4-41
Chapter 4
For parameter configuration
[Output terminal function list]
Function
code
Symbol
Function name
Description
040
ZS
Zero speed
detection
ON if output frequency is
less than set value
041
DSE
Speed deviation
over
ON if speed deviation
exceeds the set value
042
PDD
Position deviation
over
ON if position deviation
exceeds the set value
043
POK
Positioning
completed
ON if positioning is
completed
044
PCMP
Pulse count
compare match
output
ON when set value and
pulse train comparator
matches.
045
OD
Deviation over for
PID control
ON if PID control deviation
exceeds the set value
046
FBV
PID1 feedback
comparison
ON if PID feedback is
within range
047
OD2
OD:Deviation over
for PID2 control
ON if PID control deviation
exceeds the set value
048
FBV2
PID2 feedback
comparison
ON if PID feedback is
within range
049
NDc
Communication line
disconnection
ON if communication is
lost with operation keypad
050
Ai1Dc
Analog [Ai1]
disconnection
detection
ON if Analog input 1 is less
than the set value
051
Ai2Dc
Analog [Ai2]
disconnection
detection
ON if Analog input 2 is less
than the set value
052
Ai3Dc
Analog [Ai3]
disconnection
detection
ON if Analog input 3 is less
than the set value
053
Ai4Dc
Analog [Ai4]
disconnection
detection
ON if Analog input 4 is less
than the set value
054
Ai5Dc
Analog [Ai5]
disconnection
detection
ON if Analog input 5 is less
than the set value
055
Ai6Dc
Analog [Ai6]
disconnection
detection
ON if Analog input 6 is less
than the set value
056
WCAi1
Window
comparator Ai2
ON if Analog input 1 is
within range
057
WCAi2
Window
comparator Ai2
ON if Analog input 2 is
within range
058
WCAi3
Window
comparator Ai3
ON if Analog input 3 is
within range
059
WCAi4
Window
comparator Ai4
ON if Analog input 4 is
within range
060
WCAi5
Window
comparator Ai5
ON if Analog input 5 is
within range
061
WCAi6
Window
comparator Ai6
ON if Analog input 6 is
within range
062
LOG1
Logical operation
result 1
Determined by the
calculation results of two
output terminals
063
LOG2
Logical operation
result 2
064
LOG3
Logical operation
result 3
065
LOG4
Logical operation
result 4
066
LOG5
Logical operation
result 5
067
LOG6
Logical operation
result 6
068
LOG7
Logical operation
result 7
[Output terminal function list]
Function
code
Symbol
Function name
Description
069
MO1
General-purpose
output 1
Set if case of use of EzSQ
070
MO2
General-purpose
output 2
071
MO3
General-purpose
output 3
072
MO4
General-purpose
output 4
073
MO5
General-purpose
output 5
074
MO6
General-purpose
output 6
075
MO7
General-purpose
output 7
076
EMFC
Bypass mode
indicator
ON while in force
operation
077
EMBP
Speed deviation
over
ON while in bypass
operation
078
WFT
Trace function
waiting for trriger
ON while in waiting status
079
TRA
Trace function data
logging
ON while in stand-by
080
LBK
Low-battery of
keypad
ON while in low battery or
when no contain battery
on keypad
081
OVS
Over-Voltage power
Supply
ON when become
overvoltage in stop status
084
AC0
Alarm code bit-0
ON if detects low battery
Alarm information is
delivered as bit.
Use the user’s guide for
more information.
085
AC1
Alarm code bit-1
086
AC2
Alarm code bit-2
087
AC3
Alarm code bit-3
089
OD3
Deviation over for
PID control
ON when PID deviation
exceeds the value [AJ-37]
090
FBV3
PID3 feedback
comparison
ON when PID feedback is
between [AJ-38]/[AJ-39]
091
OD4
Deviation over for
PID4 control
ON when PID deviation
exceeds the value [AJ-57]
092
FBV4
PID4 feedback
comparison
ON when PID feedback is
between [AJ-58]/[AJ-59]
093
SSE
PID soft start error
ON when PID soft start
became in warning status
Summary of Contents for P1-00041-H