9. TROUBLE SHOOTING
9-21
Table 9-2 Action list for STOP Error Code 0x80
Contents logged in event log
(Event ID:800, Sourse:HFWRAS_SYS)
Cause
Action
Reset signal was input.
Detailed code = 0x9201
Forced recovery from
CPU lock
Before a message appears, check whether the
reset switch is pressed.
PCI Bus Parity Error was occurred
Detailed code = 0x9202.
Hardware NMI
Remove the extension board and replace it
with another board and recheck operation. For
the replacement work, see “6.4 Installing and
Removing Components”.
Uncorrectable Error at DIMM B2.
Detailed code = 0x9217
Uncorrectable memory
error
Check whether the main memory is mounted
correctly. If this error still occurs with the
main memory mounted correctly, it may be
due to a main memory failure. Contact the
system administrator or maintenance
personnel.
Uncorrectable Error at DIMM A2.
Detailed code = 0x9218
Summary of Contents for HF-W6500