Set and Query the Multiple Instrument Synchronization Control Function
Syntax
Command
:SYNC:CONTrol
<OFF/IN/OUT>
Query
:SYNC:CONTrol?
Response
<OFF/IN/OUT>
OFF
Turns OFF the synchronization control function.
IN
Sets the instrument as the slave device.
OUT
Sets the instrument as the master device.
Description
Command
Sets or queries the I/O settings for multiple device synchronization control.
Example
Command
:SYNC:CONT OUT
Query
:SYNC:CONT?
Response
(When HEADER ON)
:SYNC:CONTROL OUT
(When HEADER OFF)
OUT
Note
・
Reset the integration value for both the master and slaves before starting synchronized
measurement of integration.
(3)
Voltage Range
Query the Voltage Range and Auto Range
Syntax
Query
:VOLTage?
Response
<Voltage range (NR1)>;<Auto range ON/OFF>;<
Select (NR1)>
Description
Queries the voltage range setting.
Example
Query
:VOLT?
Response
(When HEADER ON)
:VOLTAGE:RANGE 15;AUTO ON;SELECT 63
(When HEADER OFF)
15; ON; 63
Note
・
You can use the
:TRANsmit:SEParator
command to change the message unit
separator from a semicolon ";" to a comma ",".
・
Instead of
: VOLtage?
, you can also use
: VOLtage1?
.
(Both of these commands perform the same operation.)
Set and Query the Voltage Auto Range
Syntax
Command
:VOLTage:AUTO
<ON/OFF>
Query
:VOLTage:AUTO?
Response
<ON/OFF>
ON
Measures the voltage in an automatic range.
OFF
Turns off the voltage automatic range operation.
Description
Command
Turns ON or OFF the voltage auto range.
Query
Returns the voltage auto range setting.
Example
Command
:VOLT:AUTO ON
Query
:VOLT:AUTO?
Response
(When HEADER ON)
:VOLTAGE:AUTO ON
(When HEADER OFF)
ON
Note
・
If you set the voltage range via a command such as :VOLTage:RANGe, the auto range
operation will be turned OFF for the specified channel.
・
You cannot change this setting during integration, while the display is held.
・
Instead of
: VOLtage:AUTO(?)
, you can also use
: VOLtage1:AUTO(?)
.
(Both of these commands perform the same operation.)