Set and Query
:MEASure?
Output Items
(Instantaneous, Maximum, and Minimum Values for Phase Angle Data)
Syntax
Instantaneous
value
:MEASure[:NORMal]:ITEM:DEG:ALL <Output item>
:MEASure[:NORMal]:ITEM:DEG:CH1(?) <Output item>
Maximum
value
:MEASure[:NORMal]:ITEM:DEG_MAX:ALL <Output item>
:MEASure[:NORMal]:ITEM:DEG_MAX:CH1(?) <Output item>
Minimum
value
:MEASure[:NORMal]:ITEM:DEG_MIN:ALL <Output item>
:MEASure[:NORMal]:ITEM:DEG_MIN:CH1(?) <Output item>
Response
<Output item (NR1)>
128
64
32
16
8
4
2
1
bit7
bit6
bit5
bit4
bit3
bit2
bit1
bit0
FND
AC
MN
ACDC
Description
Sets the phase angle data (instantaneous value, maximum value, minimum value)
output items as numerical values between 0 and 20.
For example, specify 4 to output the AC rectification or 16 to output the FND
rectification measurement value.
You can also output all rectification methods together at once. For example, you can
specify 20 to output both the AC rectification and FND rectification measurement
values at the same time.
Although NRf numerical values are accepted, values to the right of the decimal are
dropped.
If no items are specified directly via a
:MEASure?
query, the measurement values are
output based on the specification of this command.
Example
Command
:MEAS:ITEM:DEG:CH1 4
Specifies to output the instantaneous value of the AC rectified power factor.
Query
:MEAS:ITEM:DEG:CH1?
Response
(When HEADER ON)
:MEASURE:NORMAL:ITEM:DEG:CH1 4
(When HEADER OFF)
4
Set and Query
:MEASure?
Output Items
(Instantaneous, Maximum, and Minimum Values for Voltage Frequency Data)
Syntax
Instantane
ous value
:MEASure[:NORMal]:ITEM:FREQU:ALL <Output item>
:MEASure[:NORMal]:ITEM:FREQU:CH1(?) <Output item>
Maximum
value
:MEASure[:NORMal]:ITEM:FREQU_MAX:ALL <Output item>
:MEASure[:NORMal]:ITEM:FREQU_MAX:CH1(?) <Output item>
Minimum
value
:MEASure[:NORMal]:ITEM:FREQU_MIN:ALL <Output item>
:MEASure[:NORMal]:ITEM:FREQU_MIN:CH1(?) <Output item>
Response
<Output item (NR1)>
128
64
32
16
8
4
2
1
bit7
bit6
bit5
bit4
bit3
bit2
bit1
bit0
FREQU
Description
Sets the voltage frequency data (instantaneous value, maximum value, minimum
value) output items as numerical values between 0 and 1.
Although NRf numerical values are accepted, values to the right of the decimal are
dropped.
If no items are specified directly via a
:MEASure?
query, the measurement values are
output based on the specification of this command.
Example
Command
:MEAS:ITEM:FREQU:CH1 1
Specifies to output the instantaneous value of the AC/DC rectified voltage frequency.
Query
:MEAS:ITEM:FREQU:CH1?
Response
(When HEADER ON)
:MEASURE:NORMAL:ITEM:FREQU:CH1 1
(When HEADER OFF)
1