Extended Programming Guide

Alarm Panel

Time     10:09 c

Version 01

Summary of Contents for Pyronix Enforcer V10

Page 1: ...Enforcer Extended Programming Guide Alarm Panel Time 10 09 c Version 01 ...

Page 2: ...ts 10 Learning Bells 11 Program Keyfob Buttons 12 Control Arming Stations 12 Change Inputs 13 Input Attributes 14 Change Inputs Programming 14 Choose Mode 15 Choose Mode Programming 15 Install ZEMs 16 Install ZEMS Programming 16 Change Outputs 16 Change Output Programming 17 Assign Keypads Readers 17 Programming Keypads 19 Programming Readers 19 Wireless Arming Station Options 20 Change Timers 21 ...

Page 3: ...ce Diagnostics 35 Communications Diagnostics 35 Engineer Reset Options 35 Engineer Reset Options Programming 36 Alarm Response 36 Alarm Responses Programming 37 Set Up Downloading 37 Set Up Downloading via Cloud 37 Connecting to the InSite software 38 Set Up Downloading via RS232 38 Connecting to the InSite software 38 Software Revision 39 Clean Start 39 Clean Start Programming 40 Appendix A Defau...

Page 4: ...0 TECHNICAL SUPPORT If you are still experiencing issues with the installation please call our UK technical support team Please note In order to get your issue resolved quickly please have the software revision of the panel ready to give to one of our engineers Alternatively if you do not require assistance straight away you can email the team who will reply to you as soon as possible Our office h...

Page 5: ...on the screen Press A and enter the engineer code again 3 SET DATE TIME is displayed 4 Engineers Menu has been accessed When the Engineer Menu is accessed a high pitch tone is generated intermittently Please note It is essential that a factory default clean start is performed after initial power up to ensure that the correct defaults have been chosen Exiting The Engineer Menu When a Main Menu Item...

Page 6: ...RAL INFORMATION Default Codes User Blank Master Manager 2222 Engineers 1111 Initial Power Up Power up the Enforcer system an alarm will be generated Proceed to the Enforcer keypad which will display from power up 1 Once power has been applied to the Enforcer Please Wait will be displayed followed by 485 Comms Lost After approximately one minute the Enforcer will the time on the display indicating ...

Page 7: ... System Busy To access the Engineer menu on any other keypad press the key on the relevant keypad and the Engineer menu will be displayed 2 A wireless keypad can be connected to set unset LEDRKP WE The Internal Tag Reader EUR 107 The Internal tag reader can be used for setting unsetting entry control or access control Refer to the installation manual for all connections Tag Area Where a valid tag ...

Page 8: ...ke the character into a capital move cursor left clears cursor adds a space moves cursor right Engineer Function Set System Setting and unsetting the system can be done using the Engineer code 1 Press 2 Enter the Engineer code default 1111 3 Press if any faults appear 4 SET SYSTEM is displayed 5 Press 6 Select the areas to set Press 7 The setting period will begin 8 Once the timer expires and a be...

Page 9: ...iting the Engineer menu It is essential that a CLEAN START is performed after initial power up SET DATE TIME All log entries are date and time stamped This can also programmed in the Master Manager Mode The time is also shown on the LCD in Day Mode Please note Please note that powering down the system will reset the time and date information Year Month Day Hours and Minutes Enter the year month da...

Page 10: ...put programmable when the nominated button is pressed 1 Show Status GREEN Unset RED Set 3 Unset Area Unsets the chosen area 6 Personal attack Activates a personal attack activation programmed in Engineers only Please note Keyfobs are learnt in the Master Manager Menu in the function EDIT USERS Control Arming Stations Control Arming Stations learns and deletes wireless arming stations These are use...

Page 11: ...or to scroll to WIRELESS DEVICE CONTROL Press 2 Control Inputs will be displayed Press h 3 Control Bells will be displayed Press 4 Learn Devices will be displayed Press or press to access the delete menus you can either delete individual devices or delete all 5 Press or to select the bell 1 or 2 to learn and press 6 Open the wireless external siren then press and hold the LEARN button until all LE...

Page 12: ...T USERS 2 Using the output types 170 199 User Defined outputs can be activated by the keyfob buttons Refer to User Outputs function in the CHANGE OUTPUTS menu Control Arming Stations 1 Press or to scroll to WIRELESS DEVICE CONTROL Press 2 Control Inputs will be displayed Press h 3 Control Bells will be displayed Press h 4 Control Arming Stations will be displayed Press 5 Learn Devices will be disp...

Page 13: ...er supports up to four areas and can be used as follows Area A All Factory Area B Reception Only Area C Offices Only Area D Factory Floor Only Input Area Any All In some installations a common area may be required A common area is an area that only sets when other specific areas become set Example An entry and exit reception area in a building may only need to be set if both the offices and wareho...

Page 14: ...riod specified by the NAT Non Activity Time See Change Timers Confirm Group If inputs are selected into the same confirm group each input will only generate an unconfirmed alarm and will not generate a confirmed activation This is useful when two or more shock sensors are being activated by the same event If a confirm group is selected as 00 the inputs are not part of any group Input Description a...

Page 15: ...rammed Please note Alarm 4K7 Tamper 2K2 must be selected if wiring double pole to an expander EOL Range End of Line Range EOL Range Programs the panel to operate with different resistor values 0 Alarm 1K Tamper 1K 1 Alarm 4K7 Tamper 2K2 2 Alarm 4K7 Tamper 4K7 2 Wide range EOL Mode EOL Mode programs all input expanders to operate as 0 Single End of Line SEOL 1 Double End of Line DEOL Input Response...

Page 16: ...ated or referenced For example the location text maybe ZEM Kitchen ZEM Loft etc Install ZEMS Programming 1 Press or to scroll to INSTALL ZEMS Press 2 Press or to select the ZEM Address Press 3 Press or to select the ZEM8 or ZEM32 WE or No to ZEM Installed Press 4 Enter the location of the ZEM This is so it is referenced and will appear on the display if a fault occurs Press to return to ZEM addres...

Page 17: ...splayed Press to program any outputs on the zone expander or press for the next function 4 Wireless Bells will be displayed Press to program any wireless output types or press for the next function 5 Output Module Outputs will be displayed Press to address an output module or press for the next function 6 Keypad Outputs will be displayed Press to program any outputs on any additional keypads conne...

Page 18: ... The lock open time and door open time can be programmed in seconds Set point sets A Set Point means that you can program the keypad reader to set certain areas only and is used in conjunction with the areas allocated to a user code For example if a user code is programmed to operate areas A and B but the keypad reader is only programmed to set area A then the system will set only area A Selects t...

Page 19: ... to program 0 3 or press the key to return to the Engineer menu Programming Readers Set Point or Unset Only 1 Press or to scroll to ASSIGN KEYPADS READERS Press 2 Press or to select the address Press 3 Type will be displayed Press 1 to select reader Press 4 Reader is will be displayed Press 0 for Set Point or press 1 for Unset Only Press 5 Set Point Sets will be displayed Select the area s Press S...

Page 20: ...Description will be displayed Press 9 Enter Name will be displayed Enter the name of the keypad and press 10 Enter Location will be displayed Enter the location of the keypad and press 11 Press or to select another device address to program 0 3 or press the key to return to the Engineer menu Wireless Arming Station Options Tag Read Enable Enables the proximity tag reader on the wireless arming sta...

Page 21: ...CHANGE TIMERS Press 2 A Entry Time will be displayed Enter the time and press Enter the time on the required function and press for the next timer 3 Press to return to the Engineer Menu CODES AND USERS This function changes the Engineer code the Master Manager code and adds changes deletes any Duress or Guard codes Default Codes User None Master Manager 2222 Engineer 1111 Please note User codes fo...

Page 22: ...o will set If disabled the default area will be shown on the display and from here other areas can be selected Wards Access This will only be displayed if an Entry Control or Access Control reader is installed on the system If the address of the Entry Control or Access Control device is entered here then the code will be assigned to that reader only Change Engineer Code The Engineer code can be 4 ...

Page 23: ...er Alert Kps Only If this function is enabled any Alert tones will be heard on the Keypad only and not the main sounder If disabled the alert tones will heard through both Silent Technical Alert If this function is enabled then any technical alerts will be silenced e g line fault ARC call fail Use Main Sounder If enabled all volumes that are programmed as will activate on the main sounder If disab...

Page 24: ...rform a full battery load test at 7 00am each day Strobe Squawk at Set If STROBE any output programmed as STROBE ANY will activate for 5 seconds after the Enforcer has set If SQUAWK any output programmed as SIREN ANY will activate for 5 seconds after the Enforcer has set and if BOTH then any outputs programmed as STROBE ANY or SIREN ANY will activate for 5 seconds after the Enforcer has set Please...

Page 25: ...ecause Final Door is higher priority the users of every individual area must follow the Final Door route to the exit making this door a common for all areas If set to NO the exit modes will be individually programmable to each area Flexi Unset When enabled this setting will allow users to select which areas they unset from the areas that they have been permitted to unset 2 Key HU If the 1 and 7 ke...

Page 26: ...l be displayed Use or to enable disable each option and press Repeat for all functions The engineer menu will be displayed once all functions have finished System Displays This function programs the text display on the keypad for when the system is unset or an area is set The Site Name reference is programmed here which must match the site name programmed on the InSite software There are options t...

Page 27: ...al Door The Enforcer system will set when an input programmed as Final Exit is either closed if the input was opened when setting started or it is opened and closed Final door is used for the lock set operation securing the lock completes the setting procedure and unlocking starts the entry time 2 Timed Final The Enforcer system will set when a Final Exit input has been closed or when an Exit Time...

Page 28: ...ew additional details press the key If no other information is available the display will move to the next log entry Pressing will return to the main screen for that entry Please note For all Fault Codes please refer to Appendix E Reviewing Logs 1 Press or to scroll to REVIEW LOGS Press 2 Panel log will be displayed Press to display the panel log 3 The time date and event will be displayed Use or ...

Page 29: ...and 0016 Strobe Any will be tested Do battery load test The Enforcer performs a check of the battery operation every 10 seconds by dipping the power supply voltage momentarily and measuring the system voltage If the battery voltage measured is below 8 9V or the battery fuse has failed a BATTERY FAULT warning will be generated The Enforcer is programmed to perform an automatic battery load test at ...

Page 30: ...gain to go back to the Engineer Menu Soak Control Programming 1 Press or to scroll to ENGINEER TESTS Press 2 Sound to play will be displayed Press 3 Walk Test will be displayed Press 4 Soak Control will be displayed Press 5 Select the inputs that are required to be soak tested Each input should be entered following by Press once finished 6 Soak Days Left will be displayed Select the number of days...

Page 31: ...ery Load Test will be displayed Press 7 Test Outputs will be displayed Press 8 Test Communications will be displayed Press to send a test signal to the ARC 9 Press to go back to the Engineer Menu DIAGNOSTICS This option enables the engineer to perform full diagnostics on all key wired and wireless components of the system Wireless Devices View Inputs This option views the status of all wireless in...

Page 32: ...ve been analysed From this point each device is tested every 15 seconds Testing Waiting for a Battery result Good At least one month of battery life remaining Replace Battery needs to be replaced immediately Wireless Dual Frequency Menu This option shows information on whether the panel wireless ZEM are working as a Single or Dual Frequency system It will also display which inputs if any are singl...

Page 33: ...poll to the PyronixCloud Last Polled ARC Displays the time since the last successful poll to the ARC LAN or WiFi Module Wi Fi Only Signal Strength The range 0 31 indicates the signal 31 Excellent 10 Poor No Signal indicates no signal IP Address Displays the IP address of the LAN Module if installed Subnet Mask Displays the Subnet Mask of the LAN Module if installed Gateway Displays the IP address ...

Page 34: ...n 30 to 80 1 Weak signal Shows RED on the wireless Device between 10 to 30 0 Missing Shows RED on the wireless Device between 0 to 10 Waiting for device signal strength information 10 Press twice to exit and again for the next sub menu item 11 Repeat the above for View Bells Signal Strength and View Arming Station Signal Strength 12 View Inputs Battery Status Press 13 Use or to choose which inputs...

Page 35: ...exit Communications Diagnostics 1 Press or to scroll to DIAGNOSTICS Press 2 Press until Communications is displayed Press Please note For more information please refer to the Modem and Communication Guide ENGINEER RESET OPTIONS The Engineer Reset Options are used so that once an alarm has occurred the Enforcer system can only be reset by an engineer code or anti code Engineer Restore of Intruder I...

Page 36: ...layed once all functions have finished ALARM RESPONSE The Alarm Response function controls how certain activations are to perform Silent 1st Alarm If this function is selected as confirmed then the first alarm to activate on the system will be silent but only if another input activates i e a confirmed alarm then the alarm will activate and the alarm tones will be heard This option is only valid on...

Page 37: ...enable or disable and press 4 Area A start at will be displayed Press or to select the alarm responses and press Repeat for all alarm notifications 5 The Engineer menu will be displayed SET UP DOWNLOADING If required the Enforcer can be programmed remotely or directly via a PC Laptop To upload download remotely a communications module must be installed To upload download directly an RS232 must be ...

Page 38: ...l you are connecting to an appropriate name 9 Click Dial If the connection is successful the Cloud Icon will become blue A dialogue box will appear asking if you would like to create a customer click yes to continue 10 The system is now successfully connected to the Insite UDL Software Now select Data from Panel to download panel settings and proceed to make changes remotely Set Up Downloading via...

Page 39: ...are connected the display will show the software revision here Press CLEAN START It is essential that a factory default Clean Start is performed after initial power up to ensure that the correct defaults are applied Please see Appendix A for a list of all defaults for each code Clear Wireless Data If this function is not accepted then all wireless inputs wireless external sounders will be still pr...

Page 40: ...SS DATA will be displayed To delete all wireless data any inputs and bells that are learned press or press to keep the wireless data 3 CLEAR CODES will be displayed To delete default all user code tag and keyfob data press or press to keep the codes that are programmed 4 CLEAR LOGS will be displayed To delete all event log data press or press to keep the event log data ...

Page 41: ...ea B II 4 Show Status 1 Show Status 1 Lock Unlock 5 No Action 0 No Action 0 I II 6 No Action 0 Hold up 6 Lock I 7 No Action 0 No Action 0 Unlock II 8 No Action 0 No Action 0 CHANGE INPUTS Inputs All inputs unused All inputs unused Input Area A if input programmed A if input programmed Input Areas Any 0 Any 0 Input Attributes Chime No 0 No 0 Omittable No 0 No 0 Double Knock No 0 No 0 Normally Open ...

Page 42: ...L O P Siren Any 0014 Siren Any 0014 STB O P Strobe Any 0016 Strobe Any 0016 Output Module Outputs OP Mod Address OP Mod Installed No 0 No 0 Keypad Outputs Address 0 3 Output 1 Unused 0000 Unused 0000 Reader Outputs Address 1 3 Output 1 Unused 0000 Unused 0000 User Outputs User Output Type Latched 0 Latched 0 User Output Name _ _ ASSIGN KEYPADS READERS Address Address 0 Keypad 1 Addresses 1 3 Unuse...

Page 43: ...rm Time 30 30 HU Confirm Time 08 08 Strobe Time 00 00 Re Arm No 3 3 AC Signal Delay 040 040 Settle 005 005 Double Knock 10 10 Pre Alarm 030 000 Comm Fault Delay 180 020 Set Fail 040 120 Fire Siren Time 04 04 Set Fail Warning 00 00 Input NAT Days 14 14 Input NAT Hours 00 00 Wireless Supervision Time 02 24 Wireless Jamming Time 100 100 Service Time 000 000 CODES AND USERS 5 Digit PINs No 0 No 0 Chan...

Page 44: ... Sounder Yes 1 Yes 1 SYSTEM OPTIONS Site Options Set With Fault Yes 1 Yes 1 Set With Tamper No 0 Yes 1 Set with ATS Fault No 0 Yes 1 Set Fail Alarm Yes 1 Yes 1 Do Bat Load Test No 0 No 0 Strb Sqwk At Set None 0 None 0 Use Level Set Yes 1 Yes 1 Autoset Force No 0 No 0 Restrict PIN Use Yes 1 No 0 Simple Set No 0 No 0 Intelligent Set No 0 No 0 Common Lobby Yes 1 Yes 1 Flexi Unset No 0 No 0 2 Key HU N...

Page 45: ...odes A Exit Mode Final Door 1 Timed Final 2 B Exit Mode Timed 0 Timed 0 C Exit Mode Timed 0 Timed 0 D Exit Mode Timed 0 Timed 0 REVIEW LOGS ENGINEER TESTS DIAGNOSTICS ENGINEER RESTORE OPTIONS Engineer Restore Intruder No 0 No 0 Engineer Restore Hold Up No 0 No 0 Engineer Restore Tamper Yes 1 Yes 1 Engineer Restore Soak No 0 No 0 Engineer Restore Confirmed Yes 1 Yes 1 Engineer Restore Faults No 0 N...

Page 46: ...it Rearm Any 0017 Digi Channel 8 Mains Fail 0052 Mains Fail 0052 Digi Channel 9 Global Fault 1 0055 Global Fault 1 0055 Digi Channel 10 Test ATS 0064 Test ATS 0064 Digi Channel 11 16 Not Used 0000 Not Used 0000 User SMS Signalling SMS Details 1 1 Mobile Number _ _ ALARM RESPONSE Silent 1st Alarm Never 0 Never 0 Disable Confirm On Entry No 0 No 0 Area A B C D Starts At Digi 3 Digi 3 Area A B C D St...

Page 47: ...tes entry timer if system not unset before entry time expires Audible Response Full Communicator Intruder and Unconfirmed signals 08 Entry Route ER Active when set except during entry time Audible Response Full Communicator Intruder and Unconfirmed signals 09 ER Part FX When fully set A acts as Entry route input as above When part set B C D acts as Final Exit input as above 10 FX Part ER When full...

Page 48: ...fitted to the door frame in the vicinity of the lock If the initial entry door is subjected to gross attack and forced open then at the expiry of entry time only one further intruder input need to be activated to signal a sequentially confirmed alarm the Entry Shock input counts as the first to alarm The Entry Exit door contact must be opened with 10 seconds of the shock detector triggering for th...

Page 49: ...via the ATE pins this time is additional to that already applied by the ATE Please note Setting this to 250 disables line fault monitoring and will not notify at the keypad readers 0 250 seconds Set Fail Time after which Set Fail operation will be invoked if exit procedure not completed 0 255 seconds Fire Siren Time Cut off time for fire alarm 99 means endless 1 99 minutes Set Fail Warning Time fo...

Page 50: ...vice is due An engineer code will clear the message 367 days APPENDIX D OUTPUT TYPES NO TYPE ACTIVE RESTORE 0000 Not Used Permanently off 0001 Fire At alarm When a valid code is entered 0002 Hold Up Any At a HU or Duress alarm This includes keypad HU When a valid code is entered 0003 Intruder Any At alarm while system is disarmed At first valid code entry and at end of confirm time 0005 Misoperati...

Page 51: ...030 Confirmed Hold Up Any When more than one confirmed hold up activates At next code entry 0033 Entry Exit Live during any entry or exit time 0034 Lights When exit or entry timer starts 20 seconds after set unset procedure completed 0035 Follow Input When input triggers Dependent upon programming 0037 Restore 1 At code entry to set After 3 seconds 0038 Restore 2 At code entry to set When unset 00...

Page 52: ...gi At power up Live for 45 seconds only 0063 Test ATE GSM Test signalling through PSTN and GSM Activates when a test call is sent Only used for specific GSMs When test completed 0064 Test ATS For use with ATE complying with BSIA Form 175 to initiate test call to ARC by each available path Test signalling through PSTN and GSM Activates when a test call is sent When test completed 0066 ATE not used ...

Page 53: ...Low battery on radio input entered name of input shown on top line Replace the battery on the mentioned input device Siren n Wireless Low Bat Low battery on radio bell number n Replace the battery on the mentioned radio bell Input name Wireless Supervision fault Radio input whose name is shown on the top line hasn t checked in Walk test the detector perform a diagnostic signal strength test and tr...

Page 54: ...y is BLANK Keypad address does not match any keypad enabled Check keypad address noting that a keypad at address 00 must be present to program system Also check Assigning Keypads menu in Engineer mode set up correctly Keypad display normal but KEYS LOCKED OUT More than one device connected at the same address Correct addressing so that no overlaps Then power system down and up again to correctly r...

Page 55: ...ult Detection Faults FAULT DESCRIPTION SOLUTION Case Tamper XXX Case tamper switch open Secure switch closed Same method of showing the device as battery fault Communication Faults FAULT DESCRIPTION SOLUTION Control Panel Modem Fault End Station unable to communicate with Digi Modem If modem not present ensure that Disable Digi option is set to YES and DOWNLOAD MODE is set to NONE or RS232 If pres...