Terms and definitions
8
Betriebsanleitung_PS_10_60_Touch_Englisch_V1.3
65
Position
Term
Display- /
Setting value
Description
Figure 7.34
Switching temperature
Setting value
The switching temperature works as an
average value generator. This means that
from when it is first switched on, an
average temperature generation of the
external temperature begins. This runs
continuously in the background. Should
the daytime average target temperature
be exceeded, this is an indication for the
control that it should be changed to the
automatic summer mode. In general the
switching temperature conduces to switch
between winter must temperature and
summer
must
temperature
and
backwards.
Temp. increase
Setting value
Adjusting the temperature increase for
the required temperature
Due to power loss you can adjust an
addition to the must temperature
winter/summer of the tank circuit
Figure 7.35
Balance tank
Setting value
After the boiler is switched off (e.g. for
burner cleaning) there is firstly a
comparison
to
check
whether
the
required temperature (at the buffer) is
available. Should this temperature not be
reached then the boiler no longer starts
up (even if, for example, buffer below
target is not reached)
Fastrun heating
Setting value
By pressing this button the fastrun
heating is activated. That means, the
buffer is heated up to the buffer top
must temperature and so the
required
temperature
is
faster
available for the heating circuits.
The “must temperature top” is the
highest temperature demand of the
connected heating circuits as far as
they are supplied from the buffer.
Summary of Contents for pelletstar 10
Page 1: ...Operating instructions pelletstar 10 60 ...
Page 92: ...13 Notes 92 Betriebsanleitung_PS_10_60_Touch_Englisch_V1 3 13 NOTES ...
Page 93: ...Notes 13 Betriebsanleitung_PS_10_60_Touch_Englisch_V1 3 93 ...
Page 94: ...13 Notes 94 Betriebsanleitung_PS_10_60_Touch_Englisch_V1 3 ...
Page 95: ...Notes 13 Betriebsanleitung_PS_10_60_Touch_Englisch_V1 3 95 ...