8
Terms and definitions
76
Betriebsanleitung_PS_10_60_Touch_Englisch_V1.3
8.8
Net pump
Position
Term
Display- /
Setting value
Description
Figure 7.86
Existing temperature
Display value
Display of the temperature in °C of the
preceding
module
(e.g.
buffer
top
temperature by the buffer)
Required temperature
Display value
Display of the required temperature in °C
of the downstream module (e.g. buffer)
The required temperature is those
temperature which the preceding
module must make the downstream
module available
Pump
Display value
Indication of the state (ON/OFF) of the
net pump
Figure 7.87
Switch on barrier
Setting value
Setting the switch on barrier in °C for the
net pump:
Is the temperature of the preceding
module (e.g. buffer top temperature
by the buffer) higher than the
adjusted switch on barrier, the net
pump is switched on. Is this not the
case, the net pump stays switched
off.
Temp. increase
Setting value
Adjusting the temperature increase for
the required temperature
Due to power loss you can adjust an
addition to the required temperature
of the downstream module
Figure 7.88
Pump*
Display value
Indication of the state of the net pump:
When the indicator lamp lights up
the net pump is switched on
Summary of Contents for pelletstar 10
Page 1: ...Operating instructions pelletstar 10 60 ...
Page 92: ...13 Notes 92 Betriebsanleitung_PS_10_60_Touch_Englisch_V1 3 13 NOTES ...
Page 93: ...Notes 13 Betriebsanleitung_PS_10_60_Touch_Englisch_V1 3 93 ...
Page 94: ...13 Notes 94 Betriebsanleitung_PS_10_60_Touch_Englisch_V1 3 ...
Page 95: ...Notes 13 Betriebsanleitung_PS_10_60_Touch_Englisch_V1 3 95 ...