9
Fault reports and their correction
86
Betriebsanleitung_PS_10_60_Touch_Englisch_V1.3
Fault reporting on the
display
Possible cause?
Suggestions for rectifying
Sum
annoyance
F: NIVEAU SUCTION
Niveau container at the suction
container empty
Control container level
X
FAULT 89
F: COMB. ROOM SENSOR
Endswitch of the combustion
room door has been activated
–
Combustion chamber door is
open
Close
combustion
chamber door
Control endswitch
X
FAULT 90
F: WARNING ASH
DISCHARGE
Ash discharge has not been
cleaned or does not rotate
Ash container is full
Foreign
bodies
are
blocking the screw
Motor is defect
Empty the ash container
Remove foreign bodies
Replace the motor
FAULT 91
F: ERROR ASH DISCHARGE
Ash discharge has not cleaned
for several times -> system
turns off
Ash container is full
Foreign
bodies
are
blocking the screw
Motor is defect
Empty the ash container
Remove foreign bodies
Replace the motor
X
FAULT 92
F: ENDSW. ROOM
DISCHARGE
Endswitch room discharge has
been activated
Receipt motor protection
Remove foreign bodies
Use another fuel
Replace the motor
Renew the screw
X
FAULT 93