8
Terms and definitions
64
Betriebsanleitung_PS_10_60_Touch_Englisch_V1.3
8.2
Buffer module
Position
Term
Display- /
Setting value
Description
Figure 7.32
Buffer top temperature
Display value
Display of the buffer top temperature in
°C
Buffer middle temperature
Display value
Display of the buffer middle temperature
in °C
Buffer bottom temperature
Display value
Display of the buffer bottom temperature
in °C
Switching temperature
Display value
The switching temperature works as an
average value generator. This means that
from when it is first switched on, an
average temperature generation of the
external temperature begins. This runs
continuously in the background. Should
the daytime average target temperature
be exceeded, this is an indication for the
control that it should be changed to the
automatic summer mode. In general the
switching temperature conduces to switch
between winter must temperature and
summer
must
temperature
and
backwards.
Outside temperature
Display value
Display of the outside temperature in °C
Figure 7.33
Required temperature
Display value
Display of the required temperature
of the module
The required temperature is the sum
of must temperature winter/summer,
difference
temperature
and
temperature increase. (
is for the
function of the temperature manager
relevant, see chapter 6).
Buffer loading pump
Display value
Indication of the state (ON/OFF) of the
buffer loading pump
Fastrun heating
Display value
Indication of the state (OPEN/CLOSE) of
the fastrun heating valve:
The term is only visible, when in
Figure 7.35
the term “Fastrun
heating” is activated.
At the fastrun heating the buffer is
heated up to the buffer top must
temperature and so the required
temperature is faster available for
the heating circuits.
Figure 7.34
Winter must temperature
Setting value
Adjusting the must temperature for winter
in °C
Summer must temperature
Setting value
Adjusting the must temperature for
summer in °C
Difference temperature
Setting value
Temperature difference between heat
supplier (=boiler) and buffer temperature
bottom for excitation of the buffer loading
pump
Summary of Contents for pelletstar 10
Page 1: ...Operating instructions pelletstar 10 60 ...
Page 92: ...13 Notes 92 Betriebsanleitung_PS_10_60_Touch_Englisch_V1 3 13 NOTES ...
Page 93: ...Notes 13 Betriebsanleitung_PS_10_60_Touch_Englisch_V1 3 93 ...
Page 94: ...13 Notes 94 Betriebsanleitung_PS_10_60_Touch_Englisch_V1 3 ...
Page 95: ...Notes 13 Betriebsanleitung_PS_10_60_Touch_Englisch_V1 3 95 ...