8
Terms and definitions
72
Betriebsanleitung_PS_10_60_Touch_Englisch_V1.3
Position
Term
Display- /
Setting value
Description
Figure 7.50
Hot water tank priority
Setting value
Activation hot water tank priority, i.e. the
hot water tank is loaded prior compared
to the heating circuit.
Kneeling barrier
Setting value
Activation kneeling barrier, i.e. the
heating circuit is locked by durable
kneeling resp. outside the loading time.
Figure 7.52
Flow max. temperature
Setting value
Maximum Flow temperature (however
this value can be exceeded by 5 °C for
the purpose of regulation!!!)
Root point temperature
Setting value
Setting the minimum flow temperature
Flow temperature at +10°C
Setting value
Setting flow temperature at +10°C
outside temperature
Flow at adjustable outside
temperature
Setting value
Setting flow temperature at a adjustable
outside temperature
Adjustable
outside
temperature
Setting value
Heating
circuit
cut-out
temperature
setting, i.e. the outside temperature
above which the heating circuit will be
switched off.
Actual outside temperature
Display value
Indication
of
the
actual
outside
temperature in °C
Switch off temperature
Setting value
The value of the outside temperature
above which the heating circuit will be
deactivated. This should not be confused
with
the
daytime
average
target
temperature since here, only the relevant
heating circuit will be deactivated.
Figure 7.54
Heating circuit pump*
Display- / Setting
value
Indication of the state of the heating
circuit pump:
When the indicator lamp lights up
the heating circuit pump is running
Heating
circuit
mixer
OPEN*
Display- / Setting
value
Indication of the state of the heating
circuit mixer:
When the indicator lamp lights up
the heating circuit mixer is open
Heating
circuit
mixer
CLOSE*
Display- / Setting
value
Indication of the state of the heating
circuit mixer:
When the indicator lamp lights up
the heating circuit mixer is closed
8.5
Time mode
Position
Term
Display- /
Setting value
Description
Figure 7.56
Time requirement
Setting value
Is intended for the situation where no
heating circuits are connected and the
system is only being used to produce
energy. I.e. within the adjusted time
values, this is the desired boiler must
temperature.
Summary of Contents for pelletstar 10
Page 1: ...Operating instructions pelletstar 10 60 ...
Page 92: ...13 Notes 92 Betriebsanleitung_PS_10_60_Touch_Englisch_V1 3 13 NOTES ...
Page 93: ...Notes 13 Betriebsanleitung_PS_10_60_Touch_Englisch_V1 3 93 ...
Page 94: ...13 Notes 94 Betriebsanleitung_PS_10_60_Touch_Englisch_V1 3 ...
Page 95: ...Notes 13 Betriebsanleitung_PS_10_60_Touch_Englisch_V1 3 95 ...