Terms and definitions
8
Betriebsanleitung_PS_10_60_Touch_Englisch_V1.3
67
Position
Term
Display- /
Setting value
Description
Figure 7.42
Must temperature
Setting value
Adjusting the must temperature of the hot
water tank in °C
Min. loading / temperature
Setting value
Outside the loading time the hot
water tank temperature is loaded to
the adjusted min. temperature. The
condition is the activated min.
loading.
Inside the loading time the loading of
the hot water tank happens when the
hot water tank temperature is under
the value of the adjusted min.
temperature.
Temp. increase
Setting value
Adjusting the temperature increase for
the required temperature
Due to power loss you can adjust an
addition to the must temperature
winter/summer of the tank circuit
Max. loading time
Setting value
Adjusting the maximum hot water tank
loading time in hours, in which the hot
water
tank
is
loaded
on
must
temperature.
Legio temperature
Setting value
Setting value for the hot water tank
temperature (Hot water tank is
heated up to this temperature to kill
bacteria)
A deactivation of this parameter is
done by setting the temperature on
0°C.
Circulation pump
Setting value
Activation of the circulation pump
During the hot water tank loading
time the circulation pump is switched
on all 10 minutes.
The circulation pump is switched off
when the circulation temperature is
higher than the min. temperature of
the hot water tank
– 5°C resp. after 5
minutes.
Loading valve
Setting value
Activation of the loading valve
Summary of Contents for pelletstar 10
Page 1: ...Operating instructions pelletstar 10 60 ...
Page 92: ...13 Notes 92 Betriebsanleitung_PS_10_60_Touch_Englisch_V1 3 13 NOTES ...
Page 93: ...Notes 13 Betriebsanleitung_PS_10_60_Touch_Englisch_V1 3 93 ...
Page 94: ...13 Notes 94 Betriebsanleitung_PS_10_60_Touch_Englisch_V1 3 ...
Page 95: ...Notes 13 Betriebsanleitung_PS_10_60_Touch_Englisch_V1 3 95 ...