background image

The Professional’s Choice

SureFlow compact range:  
1000-C & 1000-M

Auto-Fill Catering Water Boiler

Installation And User Instructions

Summary of Contents for 1000-C

Page 1: ...The Professional s Choice SureFlow compact range 1000 C 1000 M Auto Fill Catering Water Boiler Installation And User Instructions ...

Page 2: ...AGNOSTICS 6 SERVICE TECHNICAL SUPPORT 7 GUARANTEE 7 Introduction Dear Customer Congratulations on the purchase of your Instanta machine Your new water boiler is designed to give you years of trouble free service provided that the instructions contained in this manual are followed All new series Instanta products are energy efficient simple to operate and easy to service Find out more about Instant...

Page 3: ... supervised to ensure they do not play with the appliance Always disconnect the unit from the power supply and allow it to cool down before servicing The components in the draw off tap are subject to wear tear Check periodically at least every 12 months as part of a general maintenance routine We recommend that a spare tap spring tap washer or upper tap assembly are held in case of emergencies and...

Page 4: ...rical Connection The boiler must be Earthed Your machine is supplied with a standard 13amp bonded plug with a 13amp fuse Overflow The drip tray has a limited capacity and is designed to handle small spillages and drips only Wherever possible we strongly recommend that it is connected to a permanent waste outlet using the fitting kit provided If preferred and as an alternative the overflow outlet c...

Page 5: ...ray regularly Wipe external surfaces of the boiler with a damp cloth Do not use abrasive materials on the outer surfaces Wipe the draw off tap each day to keep clean and also prevent lime scale deposits from building up around the tap outlet Maintenance Service Information Descaling The boiler should be periodically checked for scale build up see below In hard water areas the boiler should be desc...

Page 6: ... and is able to detect various fault conditions Some of these are less serious and the machine will continue to operate as normal while others are more serious and will disable the unit Before calling for service switch the machine off at the mains supply Draw off a small amount of water and then switch back on after 10 minutes If the fault does not clear call technical support for advice Light In...

Page 7: ...se events the indicator lamp will flash red or green or red and green If the problem reoccurs contact the Instanta Service Department 01704 502911 Service Technical Support Tel 01704 502911 To ensure your service enquiry is handled as efficiently as possible please have the following information available Brief description of problem Product Type model Serial Number label on right hand side of mac...

Page 8: ...INSTANTA LIMITED Canning Road Southport Merseyside PR9 7SN Tel 01704 501114 Fax 01704 501115 IB33 ISS 03 FM 36413 EMS 75807 ...

Reviews: