Technical Information

Model

1000-C

1000-M

Width

mm

218

218

Depth

mm

465

465

Height

mm

440

400

Tap 
Clearance

mm

150

150

Power 
Rating

KW

3.0

2.25

Rapid 
draw-off

Litres

5

3

Weight 
(Empty)

KG

8.9

8.4

Weight 
(Full)

KG

15.9

14

Water Inlet 
Pressure:

Bar

2 to 7

2 to 7 bar

Installation

The boiler must be installed on a level work surface 
with sufficient strength to support its weight. 
Ensure all vents are unobstructed.

Locate in an area where there is adequate space to 
use the boiler safely (e.g. free from risk of congestion 
and tripping hazards). 

Connection to Mains Water Supply:

Connect the WRAS approved water filling hose 
(3/4”BSP) to the inlet connection point on the 
back of the boiler and the other end to the mains 
water supply, via an accessible isolating tap with  
a ¾” BSP thread*.

IMPORTANT:

 If micro-bore pipe is used instead of 

the inlet hose supplied, the size must be minimum 
OD 3/8”(10mm).

The water supply must have a pressure not 
exceeding 7bar (96psi), and no lower than 2bar 
(28psi) NOTE: If your water pressure exceeds 7bar,  
fit a suitable pressure reduction valve.

We regret that Instanta cannot be held responsible 
for any machine malfunctions if the water pressure 
exceeds that stated. If in doubt, consult your water 
supply company.  

*To meet WRAS installation requirements, an approved 
single-check valve providing back-flow prevention 
protection, should be fitted at the point of connection 
between the water supply and the appliances.

Electrical Connection:

The boiler must be Earthed.

Your machine is supplied with a standard 13amp 
bonded plug with a 13amp fuse. 

Overflow:

The drip-tray has a limited capacity and is 
designed to handle small spillages and drips only. 
Wherever possible, we strongly recommend that it 
is connected to a permanent waste outlet using the 
fitting kit provided. 

If preferred, and as an alternative, the overflow-outlet 
can be connected from the back of the machine 
using an optional rear-overflow kit (Pt. No: ROFK1) 
available from Instanta Spares Department (01704 
502905).

IMPORTANT:

 Whichever overflow connection is 

chosen, the diameter of the pipe used must be 
no less than 15mm. 

Failure to connect the overflow-outlet to a  
permanent waste or drain, could lead to property 
damage from flooding.

If in all circumstances, it is absolutely not possible to 
direct the boiler overflow-outlet to a permanent waste 
or drain, then the mains water supply to the boiler 
should be isolated and the unit switched off whenever 
it is left unattended for long periods (e.g. overnight). 

Whilst every reasonable precaution is taken to 

prevent an overflow, Instanta cannot be held 

responsible for any damage caused as a result 

of incorrect installation or blockage of the 

overflow or failure to direct the overflow to  

a safe outlet.

Operation

First Use (once water and electrical connections 
have been made):

•  Switch boiler on.  

•   AMBER LIGHT will illuminate to indicate that the 

boiler is filling with water.

•   Once primed with water, the RED LIGHT will 

illuminate to show that it is heating.

•   When the boiler reaches the correct  

temperature the GREEN LIGHT will show 
 that the boiler is ready. 

4

Summary of Contents for 1000-C

Page 1: ...The Professional s Choice SureFlow compact range 1000 C 1000 M Auto Fill Catering Water Boiler Installation And User Instructions ...

Page 2: ...AGNOSTICS 6 SERVICE TECHNICAL SUPPORT 7 GUARANTEE 7 Introduction Dear Customer Congratulations on the purchase of your Instanta machine Your new water boiler is designed to give you years of trouble free service provided that the instructions contained in this manual are followed All new series Instanta products are energy efficient simple to operate and easy to service Find out more about Instant...

Page 3: ... supervised to ensure they do not play with the appliance Always disconnect the unit from the power supply and allow it to cool down before servicing The components in the draw off tap are subject to wear tear Check periodically at least every 12 months as part of a general maintenance routine We recommend that a spare tap spring tap washer or upper tap assembly are held in case of emergencies and...

Page 4: ...rical Connection The boiler must be Earthed Your machine is supplied with a standard 13amp bonded plug with a 13amp fuse Overflow The drip tray has a limited capacity and is designed to handle small spillages and drips only Wherever possible we strongly recommend that it is connected to a permanent waste outlet using the fitting kit provided If preferred and as an alternative the overflow outlet c...

Page 5: ...ray regularly Wipe external surfaces of the boiler with a damp cloth Do not use abrasive materials on the outer surfaces Wipe the draw off tap each day to keep clean and also prevent lime scale deposits from building up around the tap outlet Maintenance Service Information Descaling The boiler should be periodically checked for scale build up see below In hard water areas the boiler should be desc...

Page 6: ... and is able to detect various fault conditions Some of these are less serious and the machine will continue to operate as normal while others are more serious and will disable the unit Before calling for service switch the machine off at the mains supply Draw off a small amount of water and then switch back on after 10 minutes If the fault does not clear call technical support for advice Light In...

Page 7: ...se events the indicator lamp will flash red or green or red and green If the problem reoccurs contact the Instanta Service Department 01704 502911 Service Technical Support Tel 01704 502911 To ensure your service enquiry is handled as efficiently as possible please have the following information available Brief description of problem Product Type model Serial Number label on right hand side of mac...

Page 8: ...INSTANTA LIMITED Canning Road Southport Merseyside PR9 7SN Tel 01704 501114 Fax 01704 501115 IB33 ISS 03 FM 36413 EMS 75807 ...

Reviews: