background image

Safety Controls:

The majority of possible faults have been 
covered above. However, in certain circumstances, 
one of two different safety controls within the boiler 
may have activated;
1).  

Over-boil safety

 cut-out – activates if boiler 

produces excess steam. This can be due to: 

  • lime-scale within the tank.
  • a temporary interruption in the water supply.
  •  a faulty temperature sensor or internal 

component (triac). 

To Reset Boiler: 

Switch off at the mains power 

supply and allow the boiler to cool down for ten 
minutes before switching back on (the safety device 
should automatically reset).

Earlier Models: 

The over-boil cut-out will require a 

manual reset. Contact Instanta Technical Support 
department for assistance with this.
2).  

Boil-dry Safety 

cut-out. This operates if the boiler 

has been boiled dry, for example, due to lime scale 
build-up or water starvation. 

The boil-dry safety switch will require resetting. 
Please contact our Technical Support department for 
assistance with this.

Safety Caution: Isolate boiler from power supply 
before proceeding: 

In any of these events the indicator lamp will flash red 
or green or red and green. If the problem reoccurs 
contact the 

Instanta Service Department  

- 01704 502911

Service/Technical Support

Tel: 01704 502911

To ensure your service enquiry is handled as  
efficiently as possible, please have the following 
information available;

•  Brief description of problem.

•  Product Type (model).

•   Serial Number (label on right-hand side 

of machine). 

This is essential.

Guarantee

 

Your boiler is guaranteed for twelve months from  
date of installation.

Our guarantee includes on site labour and parts 
for problems caused by fault of manufacture and 
component failure with the following exclusions:

•   Problems caused by hard water and lime scale. 

We regret that we cannot be held responsible 
for problems caused by hard water.

•   Dripping Taps. These components are subject 

to wear and tear but in the event of a tap failing 
within twelve months of installation, we will be 
pleased to replace the tap assembly by post. 
Fitting is very simple and requires no tools.  
An engineer call out is not necessary. 

•   Accidental damage, misuse or use not in 

accordance with these instructions and damage 
caused by incorrect installation.  

The manufacturer disclaims any liability for incidental, 
or consequential damages.

6

7

Summary of Contents for 1000-C

Page 1: ...The Professional s Choice SureFlow compact range 1000 C 1000 M Auto Fill Catering Water Boiler Installation And User Instructions ...

Page 2: ...AGNOSTICS 6 SERVICE TECHNICAL SUPPORT 7 GUARANTEE 7 Introduction Dear Customer Congratulations on the purchase of your Instanta machine Your new water boiler is designed to give you years of trouble free service provided that the instructions contained in this manual are followed All new series Instanta products are energy efficient simple to operate and easy to service Find out more about Instant...

Page 3: ... supervised to ensure they do not play with the appliance Always disconnect the unit from the power supply and allow it to cool down before servicing The components in the draw off tap are subject to wear tear Check periodically at least every 12 months as part of a general maintenance routine We recommend that a spare tap spring tap washer or upper tap assembly are held in case of emergencies and...

Page 4: ...rical Connection The boiler must be Earthed Your machine is supplied with a standard 13amp bonded plug with a 13amp fuse Overflow The drip tray has a limited capacity and is designed to handle small spillages and drips only Wherever possible we strongly recommend that it is connected to a permanent waste outlet using the fitting kit provided If preferred and as an alternative the overflow outlet c...

Page 5: ...ray regularly Wipe external surfaces of the boiler with a damp cloth Do not use abrasive materials on the outer surfaces Wipe the draw off tap each day to keep clean and also prevent lime scale deposits from building up around the tap outlet Maintenance Service Information Descaling The boiler should be periodically checked for scale build up see below In hard water areas the boiler should be desc...

Page 6: ... and is able to detect various fault conditions Some of these are less serious and the machine will continue to operate as normal while others are more serious and will disable the unit Before calling for service switch the machine off at the mains supply Draw off a small amount of water and then switch back on after 10 minutes If the fault does not clear call technical support for advice Light In...

Page 7: ...se events the indicator lamp will flash red or green or red and green If the problem reoccurs contact the Instanta Service Department 01704 502911 Service Technical Support Tel 01704 502911 To ensure your service enquiry is handled as efficiently as possible please have the following information available Brief description of problem Product Type model Serial Number label on right hand side of mac...

Page 8: ...INSTANTA LIMITED Canning Road Southport Merseyside PR9 7SN Tel 01704 501114 Fax 01704 501115 IB33 ISS 03 FM 36413 EMS 75807 ...