7-4. BLOWER REPLACEMENT
1.
Remove electrical power to unit.
Remove electrical power supplied to the unit by un-
plugging the unit, or by turning off the wall circuit
breaker, or electrical shock could result.
2. Using Phillips head screwdriver, remove the side panel
closest to the controls.
3. Remove electrical wires from wire nuts.
4. Remove discs and rod from inside of unit.
(See Section 3-3.)
5. Unscrew knob and lift drive-side vent panel up and
out of unit.
6. Loosen thumb screw and pull out on fan blade and
remove from shaft.
7. Using a 7/16" nut driver, remove the nuts securing
the blower to the unit, and remove blower from unit.
8. Replace with new blower in reverse order.
NOTE
When placing fan blade back onto shaft, rotate fan blade
on the blower shaft, while holding the blower wheel in
side the control area. The fan blade should snap onto a
pin at the base of the shaft.
7-2