background image

Dimensions and Installation Information (in inches)

 

For answers to your Monogram,

® 

GE Profile

 or  

GE

®

 appliance questions, visit our website at 

ge.com or call GE Answer Center

®

 service,  

800.626.2000.

320224

Specification Revised 10/07

JTP70BM/CM/WM 

GE

®

 30" Built-In Single Convection Wall Oven

 

Listed by 

Underwriters 

Laboratories

Most 30" Wall Cabinets can be used with this unit.
Note:

 These ovens are not approved for stackable 

installations.

Note:

 Cabinets installed adjacent to wall ovens 

must have an adhesion spec of at least a 194°F 

temperature rating.
Door handle protrudes 3" from door face. Cabinets 

and drawers on adjacent 45° and 90° walls should be 

placed to avoid interference with the handle.

Installation Information:

 Before installing, consult 

installation instructions packed with product for 

current dimensional data.

Electric wall ovens are not approved for installation 

with a plug and receptacle. They must be hard 

wired in accordance with installation instructions. 

Side-by-side installations require at least 2"  

between cutouts.

CL

2 x 4 or

equivalent

runners

Suitable

bracing

to support

runners

21-5/8"

over centerline

of cabinet

(must support 275 lbs.)

Cutout width
28-1/2'' MIN.
28-5/8'' MAX.

29-3/4

C

30

Recommended 

cutout location 

32-1/2" 

from floor

21

Junction 

box

location

Allow minimum of 21'' for clearance

to adjacent corners, drawers, walls, or etc.
A=Allow 1" overlap of oven over top and bottom edges of cutout.

B=Allow 11/16"-3/4" for overlap of oven over side edges of cutout.

C=28-1/4" without trim and 28-3/4" with trim.

Conduit

(72" 

long)

5

27-1/4'' MIN.
27-5/16'' MAX.
Cutout height

A

B

23-1/2'' MIN.

Cutout depth

22'' MIN.

KW Rating

240V

4.5

208V

3.4

Breaker Size

240V

20 Amps

208V

20 Amps

CL

2 x 4 or

equivalent

runners

Suitable

bracing

to support

runners

21-5/8"

over centerline

of cabinet

(must support 275 lbs.)

Cutout width
28-1/2'' MIN.
28-5/8'' MAX.

29-3/4

C

30

Recommended 

cutout location 

32-1/2" 

from floor

21

Junction 

box

location

Allow minimum of 21'' for clearance

to adjacent corners, drawers, walls, or etc.
A=Allow 1" overlap of oven over top and bottom edges of cutout.

B=Allow 11/16"-3/4" for overlap of oven over side edges of cutout.

C=28-1/4" without trim and 28-3/4" with trim.

Conduit

(72" 

long)

5

27-1/4'' MIN.
27-5/16'' MAX.
Cutout height

A

B

23-1/2'' MIN.

Cutout depth

22'' MIN.

Reviews: