6. Check voltage as follows:
Test Points
Results
from terminal 29 to 28
The voltage
from terminal 27 to 28
should read the
from terminal 27 to 29
same at each terminal.
Replacement:
If contactor proves defective:
7. Remove the four screws securing the contactor to the
bracket and remove contactor.
8. Install new contactor, replace wires, and replace side
panel.
9. Restore power to unit.
7-7. DRIVE MOTOR
REPLACEMENT
1.
Remove electrical power to unit.
Remove electrical power supplied to the unit by unplug-
ging the unit, or by turning off the wall circuit breaker, or
electrical shock could result.
2. Remove rod and discs from unit. (See Section 3-3.)
3. Cut the three wires from the motor.
4. Using 9/16" socket, remove the bolts securing the
motor to the bracket, and pull motor from unit.