7-16. MEAT PROBE
1.
Remove electrical power to unit.
RECEPTACLE
REPLACEMENT
Remove electrical power supplied to the unit by
unplugging the unit, or by turning off the wall circuit
breaker, or electrical shock could result.
2. Remove the control side-side panel.
3. Using a 3/8" socket remove the keps nuts from
receptacle bracket and remove bracket from unit.
4. Unplug the 2-pin connector from the P-5 receptacle on
the control board.
5. Using a small Phillips-head screwdriver, remove the
screw securing the probe receptacle to the bracket.
6. Replace with new receptacle in reverse order of
previous steps.
7-17. TRANSFORMER
1. Remove electrical power supplied to unit.
Remove electrical power supplied to the unit by
unplugging the unit, or by turning off the wall circuit
breaker, or electrical shock could result.
2. Remove side panel closest to the controls.