MOD Functions
17.10 Setting up data interfaces
17
606
HEIDENHAIN | TNC 620 | ISO Programming User's Manual | 9/2016
Define behavior after receipt of ETX
(noEotAfterEtx no. 106710)
With define behavior after reception of ETX (optional) you
determine whether the EOT character is sent after the ETX
character was received.
TRUE: The EOT character is not sent
FALSE: The EOT character is sent
Settings for the transmission of data using PC
software TNCserver
Apply the following settings in machine parameter
RS232
(no. 106700):
Parameters
Selection
Data transfer rate in baud
Has to match the setting in
TNCserver
Data transmission protocol
BLOCKWISE
Data bits in each transferred
character
7 bits
Type of parity checking
EVEN
Number of stop bits
1 stop bit
Specify type of handshake:
RTS_CTS
File system for file operations
FE1
Summary of Contents for TNC 620 Programming Station
Page 4: ......
Page 5: ...Fundamentals ...
Page 28: ...Contents 28 HEIDENHAIN TNC 620 ISO Programming User s Manual 9 2016 ...
Page 57: ...1 First Steps with the TNC 620 ...
Page 77: ...2 Introduction ...
Page 110: ......
Page 111: ...3 Fundamentals file management ...
Page 166: ......
Page 167: ...4 Programming aids ...
Page 194: ......
Page 195: ...5 Tools ...
Page 234: ......
Page 235: ...6 Programming contours ...
Page 284: ......
Page 285: ...7 Data transfer from CAD files ...
Page 304: ......
Page 305: ...8 Subprograms and program section repeats ...
Page 323: ...9 Programming Q parameters ...
Page 384: ......
Page 385: ...10 Miscellaneous functions ...
Page 407: ...11 Special functions ...
Page 433: ...12 Multiple axis machining ...
Page 475: ...13 Pallet management ...
Page 480: ......
Page 481: ...14 Manual Operation and Setup ...
Page 549: ...15 Positioning with Manual Data Input ...
Page 554: ......
Page 555: ...16 Test Run and Program Run ...
Page 590: ......
Page 591: ...17 MOD Functions ...
Page 622: ......
Page 623: ...18 Tables and Overviews ...