Chapter 8 Hardware Reference
© 2017 Harmonic Inc. All rights reserved.
274
Harmonic MediaGrid Release 4.1
ContentStore 5840 and 5840A
ContentStore 5840A Rear Panel Components
Rear Panel View
Figure 8–55: ContentStore 5840A Rear Panel View
Table 8–52: ContentStore 5840A Rear Panel Components
Component
Description
1. I/O Module (2)
Two I/O modules (12 Gb/s SAS EBOD) provide connectivity to the
ContentServer 4000. The system can operate with one or two
modules. If one of the modules fails in a two module system, the
other module will continue to operate. If the ContentStore is run with
a single module, the other I/O module bay must be filled with a blank
module.
CAUTION:
With Harmonic MediaGrid 4.0, SAS cables are not
hot-swappable. When replacing or removing a SAS cable, you
must first power down the associated ContentServer controller
using SystemManager, replace or re-connect the SAS cable,
and then power on the ContentServer controller by pressing
the power button on the front panel.
2. I/O Module Power and Fault
LEDs
For a description of LED states, see
ContentStore 5840 I/O Module LEDs
3. For factory use only
4. 12 GB SAS Connectors
Use the right-hand SAS connector on each I/O module to connect to
the ContentServer.
5. External Host Port Activity LEDs
For a description of LED states, see
ContentStore 5840 I/O Module LEDs
1
6
8
7
ɋ
ɋ
2
5
4
3
9
10
11
12