Chapter 4 System Configuration
© 2017 Harmonic Inc. All rights reserved.
109
Harmonic MediaGrid Release 4.1
Running the Configuration Assistant
3. Apply power to the
ContentDirectors
by connecting both power cords to separate, isolated
power sources. Press the Power button on the front control panel of each
ContentDirector
.
The ContentDirectors take approximately five minutes to start. Wait for the power-on indicator
to light before continuing.
4. Apply power to the
High Bandwidth ContentBridge 2010F
(if part of the system) by
connecting both power cords to separate, isolated power sources. Press the power button on
the front control panel. Wait for the power-on indicator to light before continuing.
5. Apply power to the
ContentBridge 1000
(if part of the system) by pressing the power switch
on the back of the device.
6. Apply power to the ContentServers and ContentStores as follows:
Running the Configuration Assistant
The configuration assistant creates a directory structure in the /omneon/sharedsys/configfiles
directory with the configuration parameters for all of the ContentDirectors.
The configuration script asks a series of questions requiring information specific to the customer
site. Use the information from the
Harmonic MediaGrid Installation Planning Guide
to complete
the answers. Note that the assistant will display suggested responses in brackets. During the
assistant, you can use the up or down arrow keys to tab to previous responses.
Follow these steps to run the configuration assistant.
IMPORTANT:
Make sure that the completed
Harmonic MediaGrid Installation Planning Guide
is available
before continuing. Also make sure you have reviewed the information in
Getting Started with the Harmonic
MediaGrid Configuration Assistant
before continuing.
To run the configuration assistant:
1. Connect a monitor and keyboard to the first ContentDirector in your Harmonic MediaGrid
system.
CAUTION:
Do not attempt to run the Configuration Assistant remotely (for example, via SSH). You must
run the Configuration Assistant directly from the ContentDirector in order for it to successfully configure
the system.
Component
Model
ContentServer 4000
Connect the power cords to power sources. Press the
Power button on the front panel.
ContentStore 4240
Connect the power cords to power sources. Press the
Power button on the front panel.
ContentServer 3000
Connect the power cords to power sources. Press the
Power button on the control panel on the front of the
server.
ContentStore 3160
Connect the power cords to power sources. Press the
Power button on the control panel on the front of each
ContentStore.
ContentStore 5840
Connect the power cables to the power supplies and to
power sources. Move all power supply switches to the
“on” position.