Chapter 8 Hardware Reference
© 2017 Harmonic Inc. All rights reserved.
269
Harmonic MediaGrid Release 4.1
ContentStore 5840 and 5840A
Figure 8–49: ContentStore 5840 and 5840A Drawer LEDs
Table 8–47: ContentStore 5840 and 5840A Operator’s Panel LEDs and Components
Component
Description
Sideplane OK/Power
Good
Green if the sideplane card is working and there are no
power problems.
Drawer Fault
Amber if a drawer component has failed. If a drive has
failed, an amber LED will be lit on the failed drive, and the
drive should be replaced (for details, see the
Harmonic
MediaGrid Component Replacement Guide
).
If the drives are OK, contact Harmonic Technical Support
to identify the failure.
Logical Fault
Amber if there is a drive fault. Flashes amber if one or
more arrays are in an affected state.
Cable Fault
Amber if the cabling between the drawer and the back of
the enclosure has failed. Contact contact Harmonic
Technical Support to resolve the problem.
Activity Bar Graph
Shows the amount of data I/O from zero segments lit (no
I/O) to all six segments lit (maximum I/O).
Sideplane OK/
Power Good
Drawer
Fault
Logical Fault
Cable Fault
Activity Bar
Graph