-DA -145
18-8
OTHER SETTINGS
User maintenance mode
User maintenance mode has 8 items as below.
Indicates point which sensors are active.
22_5 M717
Conditions
L point sensor
The point that indicator becomes RED is L-point, when upper shaft is turned.
C point sensor
The point that indicator becomes RED is C-point, when upper shaft is turned.
Needle sensor
The point that indicator becomes RED is needle position, when moving head is
moved.
Origin point of cutter
The point that indicator becomes RED is origin point of cutter.
Origin point of thread catcher The point that indicator becomes RED is origin point of thread catcher.
Angle
Indicate angle of upper shaft.
Please use dial when you need to know precision angle.
Key
Machine movement
Change jump
Change the needle bar’s movement.
“JUMP” : Needle Jump, “DRIVE” : Needle Drive
Upper shaft turns Upper shaft turns clockwise and counterclockwise.
When release key, upper shaft stops.
Caution: please be careful that Needle move at once.
Needle change
Move the sewing head to the adjustment needle in the direction of the arrows.
Cutter Open/Close
When cutter is open position, cutter move to close position.
When cutter is close position, cutter move to open position.
Caution: please be careful that cutter move at once.
Catcher Open/Close
When catcher is open position, cutter move to close position.
When catcher is close position, cutter move to open position.
Clip-type thread holder (option)
When clip is open position, clip move to close position.
When clip is close position, clip move to open position.
Keeper When
keeper is open position, keeper move to close position.
When keeper is close position, keeper move to open position.
Standby position
In case, each equipment position without standby position, as example “Upper
shaft is not at C point, Thread cut blade is not at stop position, Thread Catcher is
open position”, this key work for back to standby position automatically.
Summary of Contents for HCD3E
Page 1: ...Industrial Single head Embroidery Machine INSTRUCTION BOOK Program Ver 2 23 HCD3E DEUC01 4 ...
Page 2: ......
Page 141: ... D2 117 13 6 FRAME CONFIRMATION 20_5 NB01 11 Press Press to return to Drive mode ...
Page 264: ... RA 110 26 3 BUILT IN FONT LIST 26_3 P401 Basic script Diacritic script ...
Page 265: ... RA 111 26 3a BUILT IN FONT LIST 26_3a P401 ...
Page 268: ......
Page 307: ......
Page 321: ......
Page 361: ......