14.2.
Additional recommendations for the - ATEX Version
valid for Ecocut 2406 - 2-stage and Ecocut 2406 - 2-stage in series
14.2.1.
Before the machine is installed, check that the flameproofing characteristics coded on the electric pump data
plate conform to the classification requirements of the installation area.
14.2.2.
Do not work on cable glands, connectors, or open the motor casing; these works are reserved to Häny au-
thorised workshops. The flameproof joints cannot be repaired. It is possible to shorten the electrical cables
while respecting a minimum length of 3000 mm (EN60079-14).
14.2.3.
The operating characteristics of these machines must comply with the characteristics specified in the name
-
plate and in the attached EX certificate.
14.2.4.
The minimum head is at the top of the electric motor for machines operating in S1 service mode; instead, a
head over the motor in case of cooling system activation is not required (always check NPSH). It is located
over the pump casing for electric pumps operating with cooling system activated.
14.2.5.
It is obligatory to connect the thermal probes to the control equipment of the electric pump. The temperature
sensor tripping must cut the electric pump power supply. Reset must not be automatic, but should be pos-
sible only after inspection by qualified staff.
If the motor is equipped with PTC probes, read the manual for information on installation.
14.2.6.
No change to the machines or replacement of parts of the electric motors is allowed. It is allowed to only
replace wet end parts (numbered L1 to L19 of the Section in question) with identical genuine parts (same
part number or same code on the part) in case of normal wear and tear. Any service other than ordinary
maintenance can only be carried out by Häny AG. The class of screws used to assemble the flameproof
casing must be A2-70 ISO 3506-1.
14.2.7.
The optional use of the conductivity sensor is conditioned on the use of a control device installed in the con-
trol panel and compliant with potentially explosive environment requirements.
14.2.8.
The electric pump is supplied with the power cable permanently connected and without switch. The electric
cable must therefore be connected to the power supply in a safe area or using one of the protection methods
provided for in the EN 60079-0 standard with a switch off button. The cable cannot be reduced in length.
14.2.9.
Activate all possible measures to prevent the following malfunctions as they could cause and trigger an ex-
plosion:
- dry running of the pump or 0/Q capacity: foresee a pressure and/or capacity probe directly connected to
the control panel with manual restarting, as to avoid the electric pump operating in such conditions;
- pump shaft bearings damage: in case of increased vibrations and/or noise during operation, stop the pump
and send it to authorized Häny workshop.
Summary of Contents for ECONEX 2402
Page 2: ......
Page 181: ...181 226 ECONEX ECOCUT ECOVOX PM1 101274 VERSION 06 15 02 2022 BG 2 2 1...
Page 188: ...188 226 ECONEX ECOCUT ECOVOX PM1 101274 VERSION 06 15 02 2022 BG TLT04112013 00 9 1 0 3 m...
Page 189: ...189 226 ECONEX ECOCUT ECOVOX PM1 101274 VERSION 06 15 02 2022 BG 9 2 3 9 3 100 cm 100 cm 3 9 4...
Page 196: ...196 226 ECONEX ECOCUT ECOVOX PM1 101274 VERSION 06 15 02 2022 BG 12 12 1 5 10 12 2 31 12 3 3...
Page 197: ...197 226 ECONEX ECOCUT ECOVOX PM1 101274 VERSION 06 15 02 2022 BG 13 104 51 52...
Page 209: ...209 226 ECONEX ECOCUT ECOVOX PM1 101274 VERSION 06 15 02 2022 BG 15 T 16 15 Nm 1 2 3 U 4 5 6 7...
Page 219: ...219 226 ECONEX ECOCUT ECOVOX PM1 101274 VERSION 06 15 02 2022...
Page 220: ...220 226 ECONEX ECOCUT ECOVOX PM1 101274 VERSION 06 15 02 2022...
Page 221: ...221 226 ECONEX ECOCUT ECOVOX PM1 101274 VERSION 06 15 02 2022...
Page 224: ...224 226 ECONEX ECOCUT ECOVOX PM1 101274 VERSION 06 15 02 2022...
Page 225: ...225 226 ECONEX ECOCUT ECOVOX PM1 101274 VERSION 06 15 02 2022...
Page 226: ...226 226 ECONEX ECOCUT ECOVOX PM1 101274 VERSION 06 15 02 2022...
Page 227: ......