x
V.
OPERATING INFORMATION
LS PHOTOLIGHT INDICATORS
FIG 5.39
The upper and lower LS photolights (fig. 5.39)
have L.E.D. lights (fig. 5.40) that indicate their operational
status.
LT/DK SWITCH –
Light/Dark switch on photolight
(fig. 5.40, item 1) changes the activated condition of
green L.E.D. (see below) from
ON
(“LT”) to
OFF
(“DK”). Switch does not affect the functional operation
of the light, only how it is displayed. Switch should be
set to “LT”.
SENSITIVITY ADJUSTMENT SCREW –
Sensitivi-
ty adjustment screw (fig. 5.40, item 2) should always
be set to maximum.
YELLOW L.E.D. –
Yellow L.E.D. (fig. 5.40, item 3)
indicates power on.
GREEN L.E.D. –
Green L.E.D. (fig. 5.40, item 4)
indicates output energized (sending a signal to Tassel-
trol
®
box, opening the raise or lower stack valve).
RED L.E.D. –
Red L.E.D. (fig. 5.40, item 5) indi-
cates photolight is receiving reflected signal.
FIG 5.40
2
1
3
4
5
PHOTO LENSES
Summary of Contents for 204
Page 133: ...x IX TROUBLE SHOOTING TASSELTROL LS SYSTEM ELECTRICAL CONTINUED FIG 9 1 1 2...
Page 134: ...x IX TROUBLE SHOOTING NOTES...
Page 140: ...138 NOTES...