247
96-8000 Rev AC
May 2010
Maintenance
TSC1000 Maintenance
Before doing any maintenance to the 1000psi system, disconnect the
power source; unplug it from the power supply.
.
Double
Lid
Standard
Pump
TSC
Pump
Auxiliary
Filter
Gate Filter
Replacement
Filters
TSC1000 / HPC1000
Check the oil level on a daily basis. If the oil is low, add oil through the fill cap
on the reservoir. Fill the reservoir about 25% full with 5-30W synthetic oil.
Auxiliary Filter Element Replacement
Change the filter bag when the filter gauge displays a vacuum level of -5 in. Hg
or more. Do not allow the suction to exceed -10 in. Hg or pump damage may
occur. Replace with a 25-micron rated filter bag (Haas P/N 93-9130).
Loosen the clamps and open the lid. Use the handle to remove the basket
(the filter element will be removed with the basket). Remove the filter element
from the basket and discard. Clean the basket. Install a new filter element and
replace the basket (with element). Close the lid and secure the clamps.