43
96-8000 Rev AC
May 2010
Operation
Hardware Check
If the software has been updated and you would like to check the Ethernet
hardware version; power up the machine and wait for the NOT READY mes
-
sage to disappear from the List/Prog menu. Press
PARAM/DGNOS
twice , then
PAGE DOWN. At the bottom of the page is the FV version; it should be 12.001
or higher.
Microsoft Network Administration
Verify in Network Neighborhood that the file serving computer can be seen on
the network from another computer. Double Click on the server name icon in
Network Neighborhood. Verify that the folder is seen for that computer name
(The folder name should be the name entered in Setting 139) on the CNC.
Verify the file serving computer privileges to this folder are shared. (Not READ
ONLY; which is a typical default).
Verifying the networking is functioning (available only on TCP/IP networks)
Turn DHCP to OFF.
Enter the Static IP address-Setting 902 and Subnet Mask-Setting 903 press
F1. Go to a computer on the network. Go to DOS (E.g. MS DOS Command
Prompt) and at the DOS prompt type in “Ping” and the same information which
was typed into Setting 902.
Example: C:>PING 192.168.1.2
Various data times will be displayed. If network time-out error occurs, verify the
settings and check the data cable(s).
M
achine
d
ata
c
ollection
Machine Data Collection is enabled by Setting 143, which allows the user to
extract data from the control using a Q command sent through the RS-232 port
(or by using an optional hardware package). This feature is software-based and
requires an additional computer to request, interpret and store data from the
control. Certain Macro variables can also be set by the remote computer.
Data Collection Using the RS-232 Port
The control only responds to a Q command when Setting 143 is ON. The fol
-
lowing output format is used:
<STX> <CSV response> <ETB> <CR/LF> <0x3E>
STX (0x02) marks the start of data. This control character is for the remote
computer.
CSV is the Comma Separated Variables, one or more data variables separated
by commas.
ETB (0x17) is the end of the data. This control character is for the remote com
-
puter.
Summary of Contents for 96-8000
Page 15: ...6 96 8000 Rev AC May 2010 Mill Warning Decals ...
Page 16: ...7 96 8000 Rev AC May 2010 Safety Lathe Warning Decals ...
Page 41: ...32 96 8000 Rev AC May 2010 ...
Page 93: ...84 96 8000 Rev AC May 2010 ...
Page 129: ...120 96 8000 Rev AC May 2010 ...
Page 133: ...124 96 8000 Rev AC May 2010 ...
Page 268: ......
Page 269: ......