188/189/190 - G51 X/Y/Z SCALE
The axes can be scaled individually using the following new settings (must be a
positive number).
Setting 188 = G51 X SCALE
Setting 189 = G51 Y SCALE
Setting 190 = G51 Z SCALE
However, if setting 71 has a value, then settings 188-190 are ignored, and the
value in setting 71 is used for scaling. If the value for setting 71 is zero, then
settings 188-190 are used. Note that when settings 188-190 are in effect only
linear interpolation, G01, is allowed. If G02 or G03 is used, alarm 467 will be
generated.
191 - Default Smoothness
This setting may be set to ROUGH, MEDIUM, or FINISH and uses parameters
302, 303, 314, 749, and 750-754 and G187 to set the smoothness and a maxi
-
mum corner rounding factor. The default values are used when not overridden
by a G187 command.
196 - Conveyor Shutdown
This specifies the amount of time to wait without activity prior to turning off the
chip conveyor (and washdown coolant, if installed). Units are minutes.
197 - Coolant Shutdown
This specifies the amount of time to wait without activity prior to Flood, Shower,
and Through-Spindle Coolant turn off in mills. Units are minutes.
199 - Backlight Timer
Specifies the time in minutes after which the machine display backlight will turn
off when there is no input at the control (except in JOG, GRAPHICS, or SLEEP
mode or when an alarm is present). Press any key to restore the screen (CAN-
CEL is preferred).
201 - Show Only Work and Tool Offsets In Use
Turning this setting on will display only the Work and Tool offsets used by the
running program. The program must be run in the graphics mode first to acti
-
vate this feature.
216 - Servo and Hydraulic Shutoff
This setting will turn the servomotors and hydraulic pump, if equipped, off after
the specified number of minutes has elapsed without activity, such as running a
program, jogging, button presses, etc. The default is 0.
238 - High Intensity Light Timer (minutes)
Specifies the amount of time, in minutes, that the High Intensity Light option
(HIL) remains turned on. It can be turned on if the door is opened and the work
light switch is on. If this values is zero, then the light will remain turned on.
900 - CNC Network Name
The control name you would like to show up on the network.
Summary of Contents for 96-8000
Page 15: ...6 96 8000 Rev AC May 2010 Mill Warning Decals ...
Page 16: ...7 96 8000 Rev AC May 2010 Safety Lathe Warning Decals ...
Page 41: ...32 96 8000 Rev AC May 2010 ...
Page 93: ...84 96 8000 Rev AC May 2010 ...
Page 129: ...120 96 8000 Rev AC May 2010 ...
Page 133: ...124 96 8000 Rev AC May 2010 ...
Page 268: ......
Page 269: ......