Excessive sparks.
Arc voltage is too low or too high.
See welding settings.
Poor earth connection.
Check and position the earth clamp as close
as possible to the area to be welded.
Insufficient gas protection.
Adjust the gas flow.
No gas coming from the torch.
Poor gas connection.
Check the connections of gas inlets.
Check that the solenoid valve is working.
Error while downloading.
The data on the USB stick is incorrect or
corrupted.
Check your data.
Backup error.
You have exceeded the maximum number of
backups.
You need to delete some programs.
The number of backups is limited to 200.
Automatic deletion of JOBS.
Some of your JOBs have been deleted
because they were incompatible with the new
pre-installed user settings (synergies).
-
USB key error.
There is no JOB detected on the USB stick.
-
The product’s memory space is full.
Free up some space on the USB key.
File error.
The file does not match the pre-installed
user settings (synergies) downloaded to the
product.
The file was created with pre-installed user
settings (synergies) that are not present on the
machine.
Update problem
The USB stick is not recognised. The visuali
-
sation of step 5 of the update procedure does
not appear on the display.
1- Insert the USB key into its socket.
2- Turn on the power source.
3- Hold down on the HMI thumbwheel to force
the update.
WARRANTY CONDITIONS
The warranty covers any defects or manufacturing faults for two years from the date of purchase (parts and labour).
The warranty does not cover:
• Any other damage caused during transport.
• The general wear and tear of parts (i.e. : cables, clamps, etc.).
• Incidents caused by misuse (incorrect power supply, dropping or dismantling).
• Environment-related faults (such as pollution, rust and dust).
In the event of a breakdown, please return the appliance to your distributor, along with:
- dated proof of purchase (receipt, invoice, etc.),