GSI Group - Laser Division
JK300HP/JK300P/JK125P
Pre-installation and User Manual
Issue 2.0
Page 78 of 172
Part No: 1EA300E01
7.4.6 Alarm 2n06 : Interlock Chain Input 6 Fault
Meaning:
For JK laser products this input is allocated to the Pump Overload. Circuit breaker supplying
the cooler pump has tripped.
Possible causes:
1. Faulty
pump.
2. Pump
overheated.
3. Loose
connection.
4.
Faulty pump connections.
There is no voltage supply to this interlock input.
Possible causes:
1.
Interlock supply not turned on.
2. Loose
connection.
3.
Faulty interlock module.
7.4.7 Alarm 2n07 : Interlock Chain Input 7 Fault
Meaning:
There is no voltage supply to this interlock input.
Possible causes:
1.
Interlock supply not turned on.
2. Loose
connection.
3.
Faulty interlock module.
7.4.8 Alarm 2n08 : Interlock Chain Input 8 Fault
Meaning:
There is no voltage supply to this interlock input.
Possible causes:
1.
Interlock supply not turned on.
2. Loose
connection.
3.
Faulty interlock module.
7.4.9 Alarm 2n09 : Interlock Chain Input 9 Fault
Meaning:
There is no voltage supply to this interlock input.
Possible causes:
1.
Interlock supply not turned on.
2. Loose
connection.
3.
Faulty interlock module.