GSI Group - Laser Division
JK300HP/JK300P/JK125P
Pre-installation and User Manual
Issue 2.0
Page 94 of 172
Part No: 1EA300E01
7.7.3 Alarm 5n03 : Shutter Configuration Failure
Meaning:
The Laser Control Card failed to set the shutter configuration.
Possible causes:
1.
Loose Shutter card.
2.
Loose Laser Control Card.
3.
Faulty Shutter Card.
4.
Faulty Laser Control Card.
7.7.4 Alarm 5n05 : Shutter Emergency Stop Fault
Meaning:
The shutter failed to enter a safe state during normal operation.
Possible causes:
1.
Loose shutter connections.
2.
Loose Shutter card.
3.
Loose Laser Control Card.
4. Faulty
shutter.
5.
Faulty Shutter Card.
6.
Faulty Laser Control Card.
7.7.5 Alarm 5n06 : Shutter Close Fault
Meaning:
The shutter failed to close in a specified period.
Possible causes:
1.
Loose shutter connections.
2.
Loose Shutter card.
3.
Loose Laser Control Card.
4. Faulty
shutter.
5.
Faulty Shutter Card.
6.
Faulty Laser Control Card.
7.8 Machine Interface Alarms (Zone 6)
TBA
Petitioners Canadian Solar Inc. and Canadian Solar (USA) Inc.
Ex. 1025, p. 94