Figure 3 - Shutter Timing
Name Description Typical
Max
T
CR
Control Response Time
300
µ
s 500
µ
s
T
SO
Time from Customer Command to
Shutter Open Acknowledge
-
50ms
See note below
T
SC
Time from Customer Command to
Shutter Closed Acknowledge
-
50ms
See note below
Note
Shutter movements do not occur during a pulse. When laser pulse widths approaching
20ms are used, shutter operation could be delayed.