8.3 Rear Mirror Tuning
Table 10 - Tuning Parameter Setup
Tuning Parameter Setup
INITIAL TUNING PARAMETERS - For all Models - Tuning The REAR MIRROR
HEIGHT - 10%
WIDTH - 5 ms
RATE - 20 Hz
OPTIMUM TUNING PARAMETERS - For All Models - Tuning The REAR MIRROR
HEIGHT - 86%
WIDTH - 0.2 ms
RATE - 10 Hz
Note
All Steps are to be performed on the UFP (Universal Front Panel) and Rear Mirror ONLY.
Step Action Button
1
On UFP Press SETUP.
2
On UFP press the DOWN button.
3
On UFP press MODIFY SHAPE.
4
Click on
HEIGHT
,
WIDTH
, and
REP
RATE
to set the correct Values
for each Parameter.
Use the parameters from Table 10.
Table 11 - Example - Tuning Parameters Set-Up
Step Action Button
1
To set-up for Height, starting at 10% select
HEIGHT 1
, which will
highlight the numbers to the right.
2
Use the Arrow Button to move the cursor to the correct location to
change the number.
3
Change the number by using the plus and minus buttons.
4
Press
HEIGHT
1
again to remove the cursor from the number and
accept the new number.
5
Check that
HEIGHT
2
is at zero, if it is not, repeat Steps 1 to 4 for
HEIGHT 2
.
6
Repeat Steps 1 to 4 to set-up
WIDTH 1
and to make sure that
WIDTH 2
is at zero.
7
Move to the next page to set-up Rep Rate.
8
Repeat Steps 1 to 4 to set-up the
REP RATE
9
Tune the
REAR MIRROR
.
10
Repeat
Step 9
for each change that is made for
HEIGHT 1
, starting
at 10% to Maximum Joules.
Petitioners Canadian Solar Inc. and Canadian Solar (USA) Inc.