AIR-TO-WATER HEAT PUMP PRODUCT
3
2.2 Water Tank
SX V D 200
L
C
J2
/
A
-
K
1 2 3 4 5
6 7
8 9
NO. Description
Options
1
Tank Used In Heat Pump
/
2
Heat Pump Water Tank for GMV
Units
/
3 Electric
Heater
/
4 Volume
Of
Tank
/
5 Stand
/
6 Pressure-Resistant
/
7
Static heating with dual coiled pipe
/
8
Design Sequence Number
/
9 Power
Supply
K=220~240V-1Ph-50Hz,
M=380~415V-3Ph-50Hz
3 FUNCTION
3.1 Cooling
In cooling mode:
the refrigerant is condensed in the outdoor unit and evaporated in
the indoor unit. Via the heat exchange with water in the indoor unit, the temperature of
water decreases and it releases heat while the refrigerant absorbs heat and
evaporates. With the help of wired controller, the outflow temperature can meet the
user’s requirement. Through the control of valve, the low-temperature water in the
system is connected with indoor fan coil and underground pipe, and exchanges heat
with the indoor air so that the indoor temperature decreases to the required range.
3.2 Heating
In heating mode:
the refrigerant evaporates in the outdoor unit and is condensed in
the indoor unit. Via the heat exchange with water in the indoor unit, the water absorbs
heat and its temperature increases while the refrigerant releases heat and is
condensed. With the help of wired controller, the outflow temperature can meet the
user’s requirement. Through the control of valve, the high-temperature water in the
system is connected with indoor fan coil and underground pipe, and exchanges heat
with the indoor air so that the indoor temperature increases to the required range;
3.3 Water Heating
In water heating mode:
the refrigerant evaporates in the outdoor unit and is
condensed in the indoor unit. Via the heat exchange with water in the indoor unit, the
water absorbs heat and its temperature increases while the refrigerant releases heat
and is condensed. With the help of wired controller, the outflow temperature can meet
the user’s requirement. Through the control of valve, the high-temperature water in the
system is connected with the coil pipe of bearing water tank, and exchanges heat with
the water in the water tank so that the temperature of water tank increases to the
required range
;
3.4 CWater Heating
When cooling mode exists together with the water heating mode, the user can set the
priority of these two modes based on the needs. The default priority is heat pump. That
is under the default setting, if cooling mode exists together with the water heating mode,
Summary of Contents for SXVD200LCJ/A-K
Page 1: ...Air to Water Heat Pump Service Manual T1 R410A 50Hz GREE ELECTRIC APPLIANCES INC OF ZHUHAI...
Page 3: ...GREE COMMERCIAL AIR CONDITIONERS AIR TO WATER HEAT PUMP PRODUCT...
Page 15: ...GREE COMMERCIAL AIR CONDITIONERS AIR TO WATER HEAT PUMP CONTROL...
Page 69: ...GREE COMMERCIAL AIR CONDITIONERS AIR TO WATER HEAT PUMP INSTALLATION...
Page 81: ...AIR TO WATER HEAT PUMP INSTALLATION 76...
Page 107: ...GREE COMMERCIAL AIR CONDITIONERS AIR TO WATER HEAT PUMP MAINTENANCE...
Page 117: ...AIR TO WATERHEATPUMP MAINTENANCE 111 6 Temperature sensor error 7 Communication Malfunction E6...
Page 121: ...AIR TO WATERHEATPUMP MAINTENANCE 115 3 1 3 Trip Fig 3 1 3 Flowchart of trip diagnosis...
Page 148: ...AIR TO WATERHEATPUMP MAINTENANCE 142 Indoor Unit 1 Front panel assy Fig 2 Fig 1 Fig 2...
Page 153: ...AIR TO WATERHEATPUMP MAINTENANCE 147 Exploded View of GRS CQ8 0Pd Na k O and GRS CQ10Pd Na K O...