9
4.1.3 Water Tank (optional)
SXVD200LC_/A-K
SXVD300LC_/A-K
SXVD200LC_/A-M SXVD300LC_/A-M
Models
J J2 J J2
Water Tank Volume
L
200
300
Electric Heater Power
W
3000
mm DN15
Outer diameter
inch 1/2
Cool Water
Inlet Pipe
Screw thread spec
1/2
″
Female BSP
mm DN15
Outer diameter
inch 1/2
Hot Water
Outlet Pipe
Screw thread
spec
1/2
″
Female BSP
mm / DN20 / DN20
Outer diameter
inch / 3/4 / 3/4
Circulation
Water Inlet/O
utlet Pipe
Screw thread spec
/
3/4
″
Female
BSP
/
3/4
″
Female
BSP
mm DN20
Outer diameter
inch 3/4
Water
Inlet/Outlet(He
at Pump) Pipe
Screw thread spec
3/4
″
Female BSP
Unit Dimension(
Φ
D
×
H) mm
Φ
540
×
1595
Φ
620
×
1620
Height mm
630
710
Width mm
1620
1645
Packing
Dimension
Depth mm
625
705
Note :
Tank is optional part, and the specific model of tank shall be selected according to local
weather and professional suggestions.
4.2 Operation Range
Mode
Range of Outdoor Temperature(
℃
)
Heating -20~35
Cooling 10~48
Water heating
-20~45
Summary of Contents for SXVD200LCJ/A-K
Page 1: ...Air to Water Heat Pump Service Manual T1 R410A 50Hz GREE ELECTRIC APPLIANCES INC OF ZHUHAI...
Page 3: ...GREE COMMERCIAL AIR CONDITIONERS AIR TO WATER HEAT PUMP PRODUCT...
Page 15: ...GREE COMMERCIAL AIR CONDITIONERS AIR TO WATER HEAT PUMP CONTROL...
Page 69: ...GREE COMMERCIAL AIR CONDITIONERS AIR TO WATER HEAT PUMP INSTALLATION...
Page 81: ...AIR TO WATER HEAT PUMP INSTALLATION 76...
Page 107: ...GREE COMMERCIAL AIR CONDITIONERS AIR TO WATER HEAT PUMP MAINTENANCE...
Page 117: ...AIR TO WATERHEATPUMP MAINTENANCE 111 6 Temperature sensor error 7 Communication Malfunction E6...
Page 121: ...AIR TO WATERHEATPUMP MAINTENANCE 115 3 1 3 Trip Fig 3 1 3 Flowchart of trip diagnosis...
Page 148: ...AIR TO WATERHEATPUMP MAINTENANCE 142 Indoor Unit 1 Front panel assy Fig 2 Fig 1 Fig 2...
Page 153: ...AIR TO WATERHEATPUMP MAINTENANCE 147 Exploded View of GRS CQ8 0Pd Na k O and GRS CQ10Pd Na K O...