GREE
GMV5 INDOOR UNIT SERVICE MANUAL
23
3.10 Slim Duct Type
Model
GMV-
ND22PL/B-T
GMV-
ND25PL/B-T
GMV-
ND28PL/B-T
GMV-
ND32PL/B-T
GMV-
ND36PL/B-T
GMV-
ND40PL/B-T
Horse Power
HP
1
1
1
1.5
1.5
1.5
Cooling capacity
kW
2.2
2.5
2.8
3.2
3.6
4.0
Heating capacity
kW
2.5
2.8
3.2
3.6
4.0
4.5
Air volume
m
3
/h
450
450
450
550
550
750
Unit external static pressure
Pa
0/0~15
0/0~15
0/0~15
0/0~15
0/0~15
0/0~15
Cooling power input
W
25
25
25
30
30
35
Cooling current input
A
0.2
0.2
0.2
0.3
0.3
0.3
Heating power input
W
25
25
25
30
30
35
Heating current input
A
0.2
0.2
0.2
0.3
0.3
0.3
*Minimum line current
A
0.25
0.25
0.25
0.38
0.38
0.38
*Maximum fuse current
A
6
6
6
6
6
6
Sound pressure level
dB(A)
30
30
30
31
31
33
Power supply
220-240V 1 phase ~50Hz/208-230V 1 phase ~60Hz
Piping
interface
Liquid pipe
mm
Φ6.35
Φ6.35
Φ6.35
Φ6.35
Φ6.35
Φ6.35
Gas pipe
mm
Φ9.52
Φ9.52
Φ9.52
Φ12.7
Φ12.7
Φ12.7
Drain pipe
External diameter
× thickness
mm
Φ25×2.5
Φ25×2.5
Φ25×2.5
Φ25×2.5
Φ25×2.5
Φ25×2.5
Dimensions
W×D×H
mm
710×450
×200
710×450
×200
710×450
×200
710×450
×200
710×450
×200
1010×450
×200
Net weight
Main body
kg
18.5
18.5
18.5
19.5
19.5
23.5
Model
GMV-
ND45PL/B-T
GMV-
ND50PL/B-T
GMV-
ND56PL/B-T
GMV-
ND63PL/B-T
GMV-
ND72PL/B-T
Horse Power
HP
2
2
2
3
3
Cooling capacity
kW
4.5
5.0
5.6
6.3
7.2
Heating capacity
kW
5.0
5.6
6.3
7.1
8.0
Unit external static pressure
Pa
0/0~15
0/0~15
0/0~15
0/0~15
0/0~15
Air volume
m
3
/h
750
750
850
850
1100
Cooling power input
W
35
35
45
45
50
Cooling current input
A
0.3
0.3
0.3
0.3
0.5
Heating power input
W
35
35
45
45
50
Heating current input
A
0.3
0.3
0.3
0.3
0.5
*Minimum line current
A
0.38
0.38
0.38
0.38
0.63
*Maximum fuse current
A
6
6
6
6
6
Sound pressure level
dB(A)
33
33
35
35
37
Power supply
220-240V 1 phase ~50Hz/208-230V 1 phase ~60Hz
Piping
interface
Liquid pipe
mm
Φ6.35
Φ6.35
Φ9.52
Φ9.52
Φ9.52
Gas pipe
mm
Φ12.7
Φ12.7
Φ15.9
Φ15.9
Φ15.9
Drain pipe
External diameter
× thickness
mm
Φ25×2.5
Φ25×2.5
Φ25×2.5
Φ25×2.5
Φ25×2.5
Dimensions
W×D×H
mm 1010×450×200 1010×450×200 1010×450×200 1010×450×200 1310×450×200
Net weight
Main body
kg
23.5
23.5
24.5
24.5
30.5
Model
GMV-
ND22PLS/B1
-T
GMV-
ND25PLS/B1
-T
GMV-
ND28PLS/B1
-T
GMV-
ND32PLS/B1
-T
GMV-
ND36PLS/B1
-T
GMV-
ND40PLS/B1
-T
Horse Power
HP
1
1
1
1.5
1.5
1.5
Cooling capacity
kW
2.2
2.5
2.8
3.2
3.6
4.0
Summary of Contents for CM100N1320
Page 1: ...Multi Variable Air Conditioners Indoor Units GC201809 VI...
Page 6: ...GREE GMV5 INDOOR UNIT SERVICE MANUAL 1 PRODUCT...
Page 50: ...GREE GMV5 INDOOR UNIT SERVICE MANUAL 45 CONTROL...
Page 51: ...GREE GMV5 INDOOR UNIT SERVICE MANUAL 46 1 Operation Flowchart...
Page 91: ...GREE GMV5 INDOOR UNIT SERVICE MANUAL 86 INSTALLATION...
Page 136: ...GREE GMV5 INDOOR UNIT SERVICE MANUAL 131 Maintenance...
Page 151: ...GREE GMV5 INDOOR UNIT SERVICE MANUAL 146 GMV ND160PHS A T GMV ND224PH A T GMV ND280PH A T...
Page 276: ...JF00302966...