GREE
GMV5 INDOOR UNIT SERVICE MANUAL
14
3.3 Low Static Pressure Duct Type
Model
GMV-
ND22P
LS/A-T
GMV-
ND25P
LS/A-T
GMV-
ND28P
LS/A-T
GMV-
ND32P
LS/A-T
GMV-
ND36P
LS/A-T
GMV-
ND40P
LS/A-T
GMV-
ND45P
LS/A-T
GMV-
ND50P
LS/A-T
GMV-
ND56P
LS/A-T
Horse Power
HP
1
1
1
1.5
1.5
1.5
2
2
2
Cooling capacity
kW
2.2
2.5
2.8
3.2
3.6
4.0
4.5
5.0
5.6
Heating capacity
kW
2.5
2.8
3.2
3.6
4.0
4.5
5.0
5.6
6.3
Air Volume
m
3
/h
450
450
450
550
550
700
700
700
1000
ESP
Pa
15/0~30 15/0~30 15/0~30 15/0~30 15/0~30 15/0~30 15/0~30 15/0~30 15/0~30
Cooling power input
W
35
35
35
43
43
52
52
52
99
Cooling current input
A
0.2
0.2
0.2
0.2
0.2
0.3
0.3
0.3
0.5
Heating power input
W
35
35
35
43
43
52
52
52
99
Heating current input
A
0.2
0.2
0.2
0.2
0.2
0.3
0.3
0.3
0.5
*Minimum line current
A
0.25
0.25
0.25
0.25
0.25
0.38
0.38
0.38
0.63
*Maximum fuse current
A
6
6
6
6
6
6
6
6
6
Sound pressure level dB(A)
31
31
31
32
32
33
33
33
35
Power supply**
220-240V 1 phase ~50Hz/208-230V 1 phase ~60Hz
Pipe
diameter
Liquid pipe mm
Φ6.35
Φ6.35
Φ6.35
Φ6.35
Φ6.35
Φ6.35
Φ6.35
Φ6.35
Φ9.52
Gas pipe
mm
Φ9.52
Φ9.52
Φ9.52
Φ12.7
Φ12.7
Φ12.7
Φ12.7
Φ12.7
Φ15.9
Drain pipe
External
diameter
×thickness
mm
Φ25×2.5 Φ25×2.5 Φ25×2.5 Φ25×2.5 Φ25×2.5 Φ25×2.5 Φ25×2.5 Φ25×2.5 Φ25×2.5
Dimensions W×D×H
mm
700×615
×200
700×615
×200
700×615
×200
700×615
×200
700×615
×200
900×615
×200
900×615
×200
900×615
×200
1100×615
×200
Net weight
kg
22
22
22
22
22
27
27
27
31
Model
GMV-
ND63PL
S/A-T
GMV-
ND71PL
S/A-T
GMV-
ND80PL
S/A-T
GMV-
ND90PL
S/A-T
GMV-
ND100P
LS/A-T
GMV-
ND112PL
S/A-T
GMV-
ND125P
LS/A-T
GMV-
ND140P
LS/A-T
Horse Power
HP
3
3
3
4
4
4
5
5
Cooling capacity
kW
6.3
7.1
8.0
9.0
10.0
11.2
12.5
14.0
Heating capacity
kW
7.1
8.0
9.0
10.0
11.2
12.5
14.0
16.0
Air volume
m
3
/h
1000
1000
1100
1500
1500
1700
2000
2000
Unit external static
pressure
Pa
15/0~30
30/0~50
30/0~50
30/0~50
30/0~50
30/0~50
30/0~50
30/0~50
Cooling power input
W
99
105
140
209
209
209
230
230
Cooling current input
A
0.5
0.5
0.7
1.0
1.0
1.0
1.1
1.1
Heating power input
W
99
105
140
209
209
209
230
230
Heating current input
A
0.5
0.5
0.7
1.0
1.0
1.0
1.1
1.1
*Minimum line current
A
0.63
0.63
0.88
1.25
1.25
1.25
1.38
1.38
*Maximum fuse current
A
6
6
6
6
6
6
6
6
Sound pressure level dB(A)
35
35
36
40
40
40
42
42
Power supply
220-240V 1 phase ~50Hz/208-230V 1 phase ~60Hz
Pipe
diameter
Liquid pipe mm
Φ9.52
Φ9.52
Φ9.52
Φ9.52
Φ9.52
Φ9.52
Φ9.52
Φ9.52
Gas pipe
mm
Φ15.9
Φ15.9
Φ15.9
Φ15.9
Φ15.9
Φ15.9
Φ15.9
Φ15.9
Summary of Contents for CM100N1320
Page 1: ...Multi Variable Air Conditioners Indoor Units GC201809 VI...
Page 6: ...GREE GMV5 INDOOR UNIT SERVICE MANUAL 1 PRODUCT...
Page 50: ...GREE GMV5 INDOOR UNIT SERVICE MANUAL 45 CONTROL...
Page 51: ...GREE GMV5 INDOOR UNIT SERVICE MANUAL 46 1 Operation Flowchart...
Page 91: ...GREE GMV5 INDOOR UNIT SERVICE MANUAL 86 INSTALLATION...
Page 136: ...GREE GMV5 INDOOR UNIT SERVICE MANUAL 131 Maintenance...
Page 151: ...GREE GMV5 INDOOR UNIT SERVICE MANUAL 146 GMV ND160PHS A T GMV ND224PH A T GMV ND280PH A T...
Page 276: ...JF00302966...