Error #11005 - WARN_LOADCELL_DROP_BELOW_MINIMUM
Description:
This warning is triggered when Float Mode detects load cell signal drops below a mini-
mum level indicating an electronics problem.
Reaction:
Handle OLED displays the warning message and Float Mode is terminated.
Cause / Remedy:
This fault is typically triggered when the load cell cable or signal wire(s) is discon-
nected or damaged. Check for:
(a) loose or damaged load cell cable to the main circuit board in the actuator
(b) loose or damaged intermedium cable, P/N 78613, to the main circuit board or the load cell analog
signal wire(s) on this cable to the drive
(c) damaged main circuit board for processing the load cell sensor
(d) damaged load cell sensor
Error #11006 WARN_UO_EXCEED_MAX_CAPACITY
Description:
This warning is triggered when User Programmable Overload attempts to tare a weight larger than
the maximum limit. The maximum limit is set at 101% of the rated capacity plus 12 lbs to account for the handle
weight.
Reaction:
The overloaded tare weight is rejected, and the maximum limit is used to set up the overload
detection parameters.
Cause / Remedy:
When TARE OVLD LMT selection from USR OVLD SUB-MENU \ CHANGE OVLD LMT in
PROGRAM MODE is selected, unit tares the current lifted weight and applies overload settings proportional to
this weight. When this error occurs the maximum limit is applied instead of the tare value to prevent the User
overload limit exceeding the maximum limit.
Please activate weight readout (WEIGHT READ ON_ under SETTINGS MENU in PROGRAM MODE) and en-
sure that the lifted weight does not exceed the maximum limit before selecting TARE OVLD LMT. This warning
does not negatively a
ff
ect system performance because overload parameters are set to the maximum allowable
settings. User can cycle the E-stop switch on the handle to clear the warning.
Error #11007 WARN_UO_BELOW_MIN_LIMIT
Description:
This warning is triggered when User Programmable Overload attempts to tare a weight less than
25% of the rated capacity.
Reaction:
The tare weight is rejected and 25% of the rated capacity is used to set up the overload detection
parameters.
Cause / Remedy:
When TARE OVLD LMT selection from USR OVLD SUB-MENU \ CHANGE OVLD LMT in
PROGRAM MODE is selected, unit tares the current lifted weight and applies overload settings proportional to
this weight. When this error occurs the 25% rated capacity value is applied instead of the tare value to prevent
the User overload limit being set below the minimum limit.
Please activate weight readout (WEIGHT READ ON_ under SETTINGS MENU in PROGRAM MODE) and
ensure that the lifted weight is not below the minimum limit before selecting TARE OVLD LMT. This warning
does not negatively a
ff
ect system performance because overload parameters are set to the minimum allowable
settings. User can cycle the E-stop switch on the handle to clear the warning.
Error #11008 WARN_SLIDE_PENDANT_TYPE_OI_MISMATCH
Description:
Slide or pendant handle sends a unique signal to the PLC to di
ff
erentiate the handle type. This
error is generated if handle type signal changes from slide to pendant or vice versa while the unit is running.
Reaction:
Unit is stopped with a warning display.
Cause / Remedy:
Replace the slide or pendant handle mother board.
Error #11009 WARN_FSH_STARTUP_TARE_WEIGHT_MISMATCH
Description:
The FSH load cell signal has deviated from zero with certain threshold value when unit is
fi
rst
booted up or e-stop is re-started.
Reaction:
N/A
Cause / Remedy:
Re-tare the FSH.
Error #11010 WARN_FSH_TARE_TIME_OUT
Description:
Tare process time out. The tare process takes time longer than the threshold value. This problem
indicates a communication problem during the tare process.
Reaction:
N/A
Cause / Remedy:
Contact Gorbel After the Sales Service if this command warning is repetitive.
G-Force® & Easy Arm Q2 - iQ2 Service Manual
Gorbel Inc.
Revised 5/21
6 - 17