![GORBEL G-Force iQ2 Series Service Manual Download Page 29](http://html1.mh-extra.com/html/gorbel/g-force-iq2-series/g-force-iq2-series_service-manual_2244890029.webp)
Error #204 - ERROR_HW_MISMATCH_PLC_MODULE
Description:
At startup, found the identi
fi
ed modules for CP 0482 PLC model do not match the known modules for
this controller.
Reaction:
Lift program terminates processing to prevent running with an incorrect con
fi
guration setup.
Cause / Remedy:
(a) Con
fi
rm the digital IO module DM 9324 is installed with the CP 0482 controller.
(b) If problem persists, replace the component.
Error #206 - ERROR_HW_MISMATCH_DRIVE_MODULE
Description:
At startup, found the identi
fi
ed ACOPOS plug-in modules do not match the known models for this
system.
Reaction:
Lift program terminates processing to prevent running with an incorrect con
fi
guration setup.
Cause / Remedy:
The designed plug-in modules are AC114, AC122, and AC131. If this error occurs:
(a) At least one unknown module is installed and should be removed.
(b) If correct modules are installed, at least one of them cannot be identi
fi
ed, possibly due to a faulty component.
Replace as necessary.
Error #207 - ERROR_HW_MOTOR_PAR_SETUP_FAULT
Description:
At startup, the con
fi
guration of the motor settings of the unit is returned with an error.
Reaction:
Lift program terminates processing to prevent running with an incorrect con
fi
guration setup.
Cause / Remedy:
Please contact Gorbel® After the Sales Service at 800-821-0086 or 585-924-6262.
A.4. Command Faults - Control Parameter Database
Error #300 - ERROR_MACHINE_STYLE_INVALID
Description:
At startup, found the stored con
fi
guration setting has an invalid machine style (i.e. G-Force®, Easy
Arm®, etc.) value.
Reaction:
Lift program terminates processing to prevent running with an incorrect con
fi
guration setup.
Cause / Remedy:
A critical con
fi
guration setting of the unit is corrupted or falsely set. Please validate the con
fi
g-
uration shown on the CONFIG page of the visualization is correct then contact Gorbel® After the Sales Service at
800-821-0086 or 585-924-6262 for further instruction.
Error #301 - ERROR_MACHINE_EA_VERSION_INVALID
Description:
At startup, found the stored con
fi
guration setting has an invalid Easy Arm® span and height version
value.
Reaction:
Lift program terminates processing to prevent running with an incorrect con
fi
guration setup.
Cause / Remedy:
A critical con
fi
guration setting of the unit is corrupted or falsely set. Please validate the con
fi
g-
uration shown on the CONFIG page of the visualization is correct then contact Gorbel® After the Sales Service at
800-821-0086 or 585-924-6262 for further instruction.
Error #302 - ERROR_MACHINE_CAPACITY_INVALID
Description:
At startup, found the stored con
fi
guration setting has an invalid capacity selection value.
Reaction:
Lift program terminates processing to prevent running with an incorrect con
fi
guration setup.
Cause / Remedy:
A critical con
fi
guration setting of the unit is corrupted or falsely set. Please validate the con
fi
g-
uration shown on the CONFIG page of the visualization is correct then contact Gorbel® After the Sales Service at
800-821-0086 or 585-924-6262 for further instruction.
Error #310 - ERROR_CONTROL_DATABASE_NOT_FOUND
Description:
At startup, found the stored con
fi
guration setting has an invalid index value to the control setting data-
base.
Reaction:
Lift program terminates processing to prevent running with an incorrect con
fi
guration setup.
Cause / Remedy:
Please contact Gorbel® After the Sales Service at 800-821-0086 or 585-924-6262.
Error #320 - ERROR_MULTI_FEATURES_PER_UNIT_CONFIGURATION
Description:
At startup, found multiple Q2/iQ2 feature con
fi
guration settings are set to use the same digital input
channel.
Reaction:
Lift program terminates processing to prevent running with an incorrect con
fi
guration setup.
Cause / Remedy:
(a) Use the extended error index number (S#) to identify which Q2/iQ2 feature contains the invalid setting (Refer
to table at end of Command Fault Error list). Please review the con
fi
guration shown on the CONFIG I/O page of the
visualization to correct the invalid setting.
(b) Please contact Gorbel® After the Sales Service at 800-821-0086 or 585-924-6262 for further instruction.
Error #321 - ERROR_MULTI_FEATURES_PER_OUTPUT_CONFIGURATION
Description:
At startup, found multiple Q2/iQ2 feature con
fi
guration settings are set to use the same digital output
channel.
G-Force® & Easy Arm Q2 - iQ2 Service Manual
Gorbel Inc.
Revised 5/21
6 - 10