3 Installation
The external temperature sensor is connected to the controller of a valve (flushing or cal-
ibration valve), for this, connect the connection valve (1) to the M8 connection (8).
Using the above-shown extension cables (9, 9943.005) the connection of several exten-
sion cables of 5m each in series can bridge a distance of max. 50 m between the tem-
perature sensor and the valve. We recommend to always minimize the distance to the
valve.
Installing the run off monitoring system
The run off monitoring system (1) detects whether the water in the run off exceeds the
maximum level determined by the installation height of the sensor.
It is connected to the controller of a valve (flushing or calibration valve), for this, connect
the connection valve (1) to the M8 connection (8).
The
function determines to which flushing valves the run off monitoring should
apply.
Using the above-shown extension cables (9, 9943.005) the connection of several exten-
sion cables of 5m each in series can bridge a distance of max. 50 m between the sensor
and the valve. We recommend to always minimize the distance to the valve.