B. Gohl
©
GEOSAT
pro
44
Go to X
– Drive the motor to the
Reference 0 (zero) position or to any
saved DiSEqC 1.2 motor position
assignments.
Press UP or DOWN NAV key to select
Local Latitude.
Press OK key and motor will drive
to the saved satellite position.
Recalculate
– Allows the user to
assign new offset 0 (zero) reference
for motor control center point.
Highlight Recalculate and press OK
key.
To clear and set a new 0 (zero)
reference position, select Yes and press
OK key. To exit without setting a new
0 (zero) reference, select No and Press
OK key.
Signal Level Reading is a measurement of electronic noise. The readings will
help determine if the receiver is correctly configured, connected to a working
LNB or LNBF and if the dish is aimed at a satellite. 0% Signal Level reading
= not connected to an LNB, receiver is incorrectly configured or connected to a
defective LNB, 45% = connected to a LNB, but dish might be misaimed, receiver
configured incorrectly or defective LNBF.
Not Connected to Working
Connected to LNBF / Not Aimed
Signal Quality Meter reading above 40% indicates the receiver is correctly
configured and the dish is aimed at the target satellite. The Signal Quality reading
should be as high as possible to provide reliable reception.
Connected to LNBF / Good Aiming