SAVE DATA
PRINT DATA
03-09-12_UIMG2 Manual ENG
11
13
00
23/07/13
23/07/13
5.5.4. CHARGING FAILURES OF STABILIZING UNIT
If a failure is detected during charging, all charging will stop. In this case the lights of the Indicator Led Bar are off.
You need to:
1. Check that AC power is present, and ensure the Power Cord is full seated in the Charge Port.
2. If AC power is present and the Indicator Led Bar is off, unplug the power cord, then remove and reseat
the Battery Pack(s).
3. If the problem persists, contact an authorized service Centre
5.5.5. REGENERATIVE BRAKING
The machine has a regenerative braking system that charges the Batteries when descending a hill or slowing
down.
When you ride down a hill, you may notice an increase in the Battery charge level.
If your Batteries are already completely full at the top of a hill, when you descend, you may feel the Speed Limiter
engage to keep the machine from overcharging its Batteries.
5.5.6. READING THE BATTERY CHARGE LEVEL DISPLAY
The horizontal bars on the left side of the Info Key Controller display indicate the levels of the charge.
The figure shows how the Battery Gauge on the Info Key Controller changes as the Battery is depleted.
The more charge the Batteries contain, the more horizontal bars are shown. If the battery charge level is very low,
the machine will notify you of a pending empty Battery condition prior to initiating safety shutdown.
Do not ride the machine if there is inadequate charge in the Batteries (indicated by the unhappy face
icon on the Info Key Controller and no dark horizontal lines on the Battery Charge display).
Carefully monitor your battery gauge and be prepared to stabilize your machine lowering the
parking stand legs if your battery charge becomes completely depleted.