Chapter 2. Installation
30
PanaFlow™ LC User’s Manual
8.
Secure Black wire of channel two downstream RG62 cable to the CH2 (blue box in Figure 41) RTN
terminal directly below the DN terminal of the XMT1000 backplane.
9.
Secure red wire of channel two upstream RG62 cable to the CH2 (blue box in Figure 41) UP terminal of
the XMT1000 backplane.
10.
Secure Black wire of channel two upstream RG62 cable to the CH2 (blue box in Figure 41) RTN
terminal directly above the UP terminal of the XMT1000 backplane.
Figure 43: PanaFlow LC2 Channel Set Up
2.11.4 Three Channel Set Up
Components of a three channel PanaFlow LC will be: a meter head, 6 conductor “trunk” cable, 3 channel
junction box, 6 transducer cables and 3 sets of transducers and clamping fixtures. Mount meter head and
junction box to a two inch post using included hardware or another location following local electrical and
building codes.
Install transducers as mentioned in Section 2.7 through Section 2.9. Prepare to wire transducer cables.
Note:
US/ Canada installations will be required to provide conduit per their particular location. European
installations will include armored cable.
2.11.4.1 Transducer Wiring (ATEX installations)
1.
Thread MCX end of 6 conductor cable trunk into XMT1000 meter head and the BNC connector end of
the cable into the 3 channel Junction box as seen in Figure 44.
CH2
CH1
Summary of Contents for Baker Hughes PanaFlow LC XMT1000
Page 1: ...Flow 910 327 Rev A Sep 2019 bhge com PanaFlow LC User s Manual ...
Page 2: ......
Page 4: ...ii no content intended for this page ...
Page 10: ...Contents viii PanaFlow LC User s Manual ...
Page 14: ...Preface xii PanaFlow LC User s Manual no content intended for this page ...
Page 142: ...Appendix E CE Mark Compliance 128 PanaFlow LC User s Manual no content intended for this page ...
Page 182: ...Warranty 168 PanaFlow LC User s Manual no content intended for this page ...
Page 189: ......