Chapter 3. Programming
66
PanaFlow™ LC User’s Manual
3.6.6b Programming the Placement
The
Placement
menu allows the user to configure the mounting method of the transducers, based on the
Transducer and Pipe programming done as specified in sections “Programming Menu Options” on page 60
and “Programming the Transducer” on page 65.
1.
Refer to Figure 75, select
[Placement]
and press
[ENTER]
.
2.
Program the
[No. of Traverses]
based on your transducer installation and transducer configuration.
Refer to Figure 73 for possible Traverse configurations supported in the meter. Typically, a
two-traverse installation is used.
3.
The
[Spacing]
shows the value calculated by the XMT1000 for the correct distance between the
upstream and downstream transducers, based on your programmed transducer, fluid and pipe data.
This is the physical spacing value that should be used when installing your transducer clamping
Table 19: Standard Transducers
Transducer Number
Transducer Model Number
15
(#15/115) C-PT-05-H
16
(#16/116) C-PT-10-H
17
(#17/117) C-PT-20-H
23
C-LP-40-HM
24
C-LP-40-NM
312
C-RW-312
318
C-RW-318
401
C-RS-401
402
C-RS-402
403
C-RS-403
407
UTXDR-407
408
UTXDR-408
505
C-RR-505
510
C-RR-510
520
C-RR-520
591
C-RR-591
592
C-RR-592
595
C-RR-H-595
596
C-RR-H-596
597
C-RR-H-597
601
C-AT-601
602
C-AT-602
603
C-AT-603
Summary of Contents for Baker Hughes PanaFlow LC XMT1000
Page 1: ...Flow 910 327 Rev A Sep 2019 bhge com PanaFlow LC User s Manual ...
Page 2: ......
Page 4: ...ii no content intended for this page ...
Page 10: ...Contents viii PanaFlow LC User s Manual ...
Page 14: ...Preface xii PanaFlow LC User s Manual no content intended for this page ...
Page 142: ...Appendix E CE Mark Compliance 128 PanaFlow LC User s Manual no content intended for this page ...
Page 182: ...Warranty 168 PanaFlow LC User s Manual no content intended for this page ...
Page 189: ......