G.1 Introduction
Wireless HART
is a bi-directional digital communication protocol for field devices, that offers multi-vendor,
inter-operable wireless standard. It is an advancement in technologies for process control systems and is
widely employed by numerous field devices.
The XMT1000 flowmeter has integrated HART communication with 4-20mA output. Masoneilan VECTOR
V1100 Wireless HART adaptor is used along with XMT1000 Flowmeter to setup as Wireless HART node. The
below steps will guide to configure XMT1000 flowmeter to work with the Masoneilan VECTOR adaptor.
G.2 Installation and Configuration
The following instruments are required for complete setup:
•
XMT1000 Flowmeter with HART option
•
Masoneilan VECTOR V1100 Wireless HART adaptor.
G.2.1 XMT1000 to Masoneilan VECTOR Connection
Note:
Make sure to add the 250
Ω
resistor across the white and yellow wires.