1.6.5 SHIELD TERMINATION TECHNIQUE – METHOD B.2
(DAISY CHAIN-QUICK TERM)
In rare situations where more flat braids need to be terminated for a connector
than three per ring terminal it is allowable to daisy chain a maximum of two shields
together before terminating to the ring terminal (Figure 1-27). All other restrictions
and instructions for the shield termination set forth in Method B.1 are still applicable.
NOTE:
The maximum length of the combined braids should be 4 inches.
Figure 1-27 Shield Termination Technique Method B.2