69
6-5. Auto Seq Time
CDR-16T have a user programmable sequential switcher that determines how long a channel or
split pattern channel group is output to the monitor before switchover (camera dwell time) to the
next channel or channel group in the sequence. See sec. ‘5-1. Accessing MAIN Menu’ for
information on making menu selections.
Where:
①
SPLIT
Sets time between switchover of split pattern groups when split pattern display selected and
auto sequence initiated. Setting range is 1 – 30 sec. See sec. ‘4-5-4. Channel Group Auto
Sequence’ for switchover examples.
②
FULL
Sets switchover time for each full screen camera channel when full screen display selected and
auto sequence initiated. If any channel set to 0 sec., result will be the same as when channel is
skipped (no display). Setting range is 0 – 30 sec. See sec. ‘4-4-2. Auto Sequence’ for switchover
example.
Important
A dwell time setting of 0 sec. for full screen channels will
effect split screen auto sequence as follows: If channel
group has at least 1 other input (full screen dwell time not
set to 0 sec.) not displayed as black, channel group auto
sequences according to split screen dwell time setting.
Channel set to 0 sec. (full screen dwell time) is displayed.
If channel group has all other inputs displayed as black,
channel group automatically skipped during auto
sequence. See sec. ‘4-5-4. Channel Group Auto
Sequence’ for more details and examples.
[AUTO SEQ TIME]
SPLIT–1S
FULL
CH1--
5S
CH2--
3S
CH3--
5S
CH4--
3S
CH5--
5S
CH6--
3S
CH7--
5S
CH8--
0S
CH9--
5S
CH10-
3S
CH11-
5S
CH12-
0S
CH13-
10S
CH14-
10S
CH15-
10S
CH16-
10S
SET
EXIT
①