51
OFF
Continues to record normally.
LAST CHANNEL
Records last camera in alarm. (When multiple alarms, switches
over from camera in alarm to new alarm input.) Settings
required in TRIGGER sub menu accessed at
⑪
following.
SWITCHOVER
Alternately switches between alarm channels when multiple
alarms occur at same time. Settings required in TRIGGER sub
menu accessed at
⑪
following.
ALL CHANNEL
Records all channels except SKIP set channels. (If alarm
occurs at SKIP set channel that channel is recorded.) Settings
required in TRIGGER sub menu accessed at
⑪
following.
PRIORITY
Same as ALL CHANNEL except alarm channels recorded
FAST, other channels NORM. Settings required in TRIGGER
sub menu accessed at
⑪
following.
SEQUENCE
Cameras recorded, and time each camera recorded,
determined by alarm device input and settings made in ALARM
SEQ REC sub menu accessed at
⑫
following.
⑩
ALARM QUALITY
Sets record quality level alarm recording. Settings to one of the four listed in sec. ‘6-3. Record
Programming’ previously.
⑪
TRIGGER
Sets which type of input trigger will initiate alarm record operation. See sec. ‘6-3-6. Regarding
Trigger Setting’ for details.
OFF
Alarm record operation not initiated.
ALARM
Input via external sensor devices (rear panel alarm input
connector) initiates alarm record operation.
SENSOR
Input via sensor board installed to CDR-16T initiates alarm
record operation.
ALM / SENS
Input via sensor devices and sensor board initiates alarm record
operation.
⑫
ALARM SEQ REC
Sub menu accessed here is only used when ALARM REC MODE
⑨
is set to SEQUENCE. In
this menu, ALARM1 – 4 correspond to alarm inputs from devices that are not mounted to
your observation cameras.
Up to 4 cameras can be programmed per each alarm reference (ALARM1 – 4). Record time
for each of the cameras related to ALARM1 – 4 can be independently set (1-30 sec.). See
sec. ‘6-3-7. Regarding Continuous Record Setting’ for details.