63
6-3-7. Regarding Continuous Record Setting
Continuous record means that record will be continuously performed from the start to stop
times set in the record program (see sec. ‘6-3-1. Continuous Record’) using the record
parameters contained in the program. If you have set REC MODE to CONTINUOUS, you will
have 6 possible ways (6 settings) for record to change (or not change) upon alarm input. If
REC MODE is set to change upon alarm input,
alarm record will be performed at ‘real
time ’
,
60 fields / sec. for NTSC and 50 fields / sec. for PAL.
Related setting (OFF, LAST CHANNEL, SWITCHOVER, ALL CHANNEL, PRIORITY or
SEQUENCE) is made at ALARM REC MODE. Alarm rec. mode sets record response upon
alarm input from one or more cameras.
Important
If ALARM REC MODE is set to LAST CHANNEL,
SWITCHOVER, ALL CHANNEL or PRIORITY, you must
also make settings in TRIGGER sub menu (see sec.
‘6-3-6. Regarding Trigger Setting’).
If ALARM REC MODE is set to SEQUENCE, you must
also make settings in ALARM SEQ REC sub menu
shown following.
◇
ALARM REC MODE Settings
u
Off
Recording continues according to the parameters set in the record program.
u
LAST CHANNEL
In this case, record will go to camera in alarm and record it until alarm reset
or
until another
alarm occurs.
(Continued following page.)
Alarm input
Record
CH1 - 16
Alarm record
(MODE setting
applied here)
Record
CH1 - 16
Alarm reset
Record
CH1 - 16
CH1
only record
CH2
only record
Record
CH1 - 16
CH2
Alarm
input
Alarm 2 reset
CH1
Alarm
input
Alarm video (realtime)
Alarm 1
reset