78
⑦
LOSS RESET
Sets how long video loss conditions exist before alarm reset and return to normal operation.
Reset range is 1 sec. to 29 min. 59 sec.
⑧
SENSOR RESET
Sets how long alarm conditions exist before sensor alarm reset and return to normal
operation.
If SENSOR INPUT
②
to TRIG, reset range is 1 sec. to 29 min. 59 sec.
If SENSOR INPUT
②
to LEVEL, setting here will be operationally invalid.
6-9-2. Regarding Alarm Display
Response examples for the three available alarm display settings are as shown below.
u
FULL
Full screen display of each alarm channel.
◇
Example:
CH1 and CH2 alarm occurrence times overlap. Display changes between channels every
1sec. during alarm overlap interval.
u
STAY
Display locks on last channel in alarm and continues to display last alarm channel even after
alarm conditions are reset.
u
SPLIT
Display goes to appropriate split screen to show all cameras in alarm at same time.
(Continued following page.)
Normal
Operation
CH1 full
screen
CH
1
CH
2
CH
1
CH
2
CH2 full
screen
Normal
Operation
CH2
Alarm
input
CH2 Alarm reset
CH1
Alarm
input
Changes every sec.
CH1
Alarm
reset
Normal
Operation
CH1 full
screen
CH2 full
screen
(until operator cleared)
CH2
Alarm
input
CH2 Alarm reset
CH1
Alarm
input
CH1
Alarm
reset